A technique combining both atomic force microscopy (AFM) and scanning electron microscopy (SEM) is used to evaluate the mechanical properties of individual collagen fibrils from the fractured surface of antler. SEM is used to locate individual mineralized collagen fibrils and allow visualization of the attachment of these fibrils to the end of an AFM probe. Tensile testing of individual collagen fibril to failure was performed using the AFM with resultant stress-strain curves obtained. Tensile strengths of up to 0.18GPa are found for some individual collagen fibrils, indicating the presence of mineral in improving mechanical performance. Consideration of the SEM operating parameters indicates that the amount of time the sample is within the SEM vacuum can affect the resultant mechanical behavior of individual fibrils.