No CrossRef data available.
Article contents
Characterization of Plasticity in Bimaterial Interface Fracture by STM
Published online by Cambridge University Press: 25 February 2011
Abstract
The Scanning Tunneling Microscope was used as a surface profilometer to image fractured interfaces of a model metal/ceramic system, Au/sapphire. By characterizing the metal side of interface fracture, features related to plastic deformation were quantified. The spatial resolution of STM allowed these measurements to be made down to the nanometer scale. Mathematical techniques were developed to characterize surface features on several size scales and to relate them to the mechanisms from which they were produced.
- Type
- Research Article
- Information
- Copyright
- Copyright © Materials Research Society 1992