Hostname: page-component-78c5997874-fbnjt Total loading time: 0 Render date: 2024-11-03T05:00:16.240Z Has data issue: false hasContentIssue false

Biomedical Potential of a Zirconium-Based Bulk Metallic Glass

Published online by Cambridge University Press:  11 February 2011

J. A. Horton
Affiliation:
Metals and Ceramics Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831–6115
D. E. Parsell
Affiliation:
University of Mississippi Medical Center, 2500 N.State St., Jackson, Miss. 39216
Get access

Abstract

Due to their unique mechanical properties, bulk metallic glasses (BMG) have potential for biomedical applications. Biocompatibility and corrosion tests of a zirconium-based BMG showed comparable behavior to current implant alloys. Mechanical properties, such as an elastic limit of 2% and a yield strength of 1700 MPa, are significantly higher than current implant alloys. In addition, it was found that medical MRI images of BMG, possibly due to the amorphous structure, are significantly better than other alloys even though the reference alloy contains 14.6 at.% Ni. Nickel-free compositions also retained similar glass forming characteristics and showed even better MRI images. Edge holding for cutting tool applications was demonstrated. Fatigue tests were performed in simulated body conditions and directly compared to Ti-6 Al-4 V. While one specimen failed at more than 3,000,000 cycles at 500 MPa, there was much scatter in the data. Further concentration on processing issues to produce pore free material is needed to produce reliable materialfor prototype development. Potential uses, especially associated with an interventional MRI for MRI guided surgeries, will be discussed.

Type
Research Article
Copyright
Copyright © Materials Research Society 2003

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Inoue, A., Mater. Trans. JIM, 36, 866 (1995).Google Scholar
2. Johnson, W. L., Mats. Sci. Forum Vols. 225–227, 3550 (1996).Google Scholar
3. Liu, C.T., Heatherly, L., Easton, D.S., Carmichael, C.A., Schneibel, J.H., Chen, C.H., Wright, J.L., Yoo, M.H., Horton, J.A., and Inoue, A., Met Trans. A. 29A, 18111819 (1998).Google Scholar
4. Ahmed, T., Long, M., Silvestri, J., Ruiz, C. and Rack, H. J., Titanium 95: Science and Technology, (The Institute of Materials, ed. by Blenkinsop, P.A., Evans, W. J., and Flower, H. M.) (1995) pp.17601767.Google Scholar
5. Thompson, J. R. (unpublished work).Google Scholar
6. Schenk, J.F., Med. Phys. 23, #6, 815850 (1996).Google Scholar