Hostname: page-component-586b7cd67f-t8hqh Total loading time: 0 Render date: 2024-11-29T07:35:19.739Z Has data issue: false hasContentIssue false

Biocompatibility of Modified Polyetheretherketone (Peek-Wc) Membranes: Human Plasma Adsorption

Published online by Cambridge University Press:  11 February 2011

Loredana De Bartolo
Affiliation:
Research Institute on Membrane Technology, ITM-CNR, c/o University of Calabria, via P. Bucci cubo 17/C, 87030 Rende (CS) Italy- Tel: +39 0984 492010; Fax. +39 0984 402103 e-mail: [email protected]
Annarosa Gugliuzza
Affiliation:
Research Institute on Membrane Technology, ITM-CNR, c/o University of Calabria, via P. Bucci cubo 17/C, 87030 Rende (CS) Italy- Tel: +39 0984 492010; Fax. +39 0984 402103 e-mail: [email protected]
Beatrice Cirillo
Affiliation:
Research Institute on Membrane Technology, ITM-CNR, c/o University of Calabria, via P. Bucci cubo 17/C, 87030 Rende (CS) Italy- Tel: +39 0984 492010; Fax. +39 0984 402103 e-mail: [email protected]
Sabrina Morelli
Affiliation:
Research Institute on Membrane Technology, ITM-CNR, c/o University of Calabria, via P. Bucci cubo 17/C, 87030 Rende (CS) Italy- Tel: +39 0984 492010; Fax. +39 0984 402103 e-mail: [email protected]
Enrico Drioli
Affiliation:
Research Institute on Membrane Technology, ITM-CNR, c/o University of Calabria, via P. Bucci cubo 17/C, 87030 Rende (CS) Italy- Tel: +39 0984 492010; Fax. +39 0984 402103 e-mail: [email protected]
Get access

Abstract

Polymeric membranes are widely used in biomedical field for bioartificial organs, medical devices and disposable clinical apparatus. Clinical utilization of blood-contacting devices requires the development of biomaterials with improved blood compatibility. The aim of this work was the exploration of a potential biocompatible membrane derived from a modified polyetheretherketone such as PEEK-WC. The surface affinity of this membrane to human plasma and plasmatic proteins such as albumin, fibrinogen and immunoglobulin G was compared to that of some commercial membranes. Changes with time of the membrane interfacial properties were evaluated by means of contact angle measurements using human protein solutions and human plasma. The extent of plasma protein adsorption on all investigated membranes was measured by comparing the behavior of the different polymer surfaces when contacting the three plasmatic proteins.

Type
Research Article
Copyright
Copyright © Materials Research Society 2003

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. De Bartolo, L. and Drioli, E.,” Membranes in artificial organs”, New Biomedical Materials -Basic and Applied Studies, eds. Haris, P.I. and Chapman, D. (IOS Press, 1998) pp. 167181.Google Scholar
2. De Bartolo, L., Jarosch-Von Schweder, G., Haverich, A. and Bader, A., Biotechnol. Progr. 16(1), 102 (2000).Google Scholar
3. Mowery, K.A., Schoenfish, M.H., Saavedra, J.E., Keefer, L.K., Meyerhoff, M.E., Biomaterials 21, 9 (2000).Google Scholar
4. Shen, M., Martinson, L., Wagner, M.S., Castner, D.G., Ratner, B.D. and Horbett, T.A., J. Biomater. Sci. Polym. Edn. 13(4), 367 (2002).Google Scholar
5. Gugliuzza, A., Clarizia, G., Golemme, G. and Drioli, E., Eur. Pol. J. 38, 235 (2002).Google Scholar
6. De Bartolo, L., Catapano, G., Della Volpe, C. and Drioli, E., E., , J. Biomat. Sci. - Polymer Edn. 10(6), 641 (1999).Google Scholar
7. De Bartolo, L., Morelli, S., Bader, A. and Drioli, E., J. Mater. Sci.-Mater. Med. 12, 959 (2001).Google Scholar
8. De Bartolo, L., Morelli, S., Bader, A., Drioli, E., Biomaterials; 23 (12) 2485 (2002).Google Scholar
9. Andrade, J.D., Hlady, V., Wei, A.P., Ho, C-H., Lea, A.S., Jeon, S.I., Lin, Y.S., Stroup, E., Clin. Mater. 11, 67 (1992).Google Scholar
10. Annarelli, C.C., Fornazero, J., Cohen, R., Bert, J., Besse, J.L., J. Coll. Interf. Sci. 213, 386 (1999).Google Scholar
11. van Oss CJ. Interfacial Forces in Aqueous Media. (Marcel Dekker 1994).Google Scholar
12. Jansen, B., Ellinghor, G., J. Biomed. Mater. Res.; 18 655 (1984).Google Scholar
13. Lee, J.H., Lee, H.B., J. Biomed. Mater. Res.; 41 304 (1998).Google Scholar