Accelerated Reliability Test Inputs in Analyzing the Device Response of MgZnO Based UV Detector

Published online by Cambridge University Press:  01 February 2011

S.S. Hullavarad
Affiliation:
Center for Superconductivity Research, Department. of Physics, University of Maryland, College Park, MD, 20742
I. Takeuchi
Affiliation:
Center for Superconductivity Research, Department. of Physics, University of Maryland, College Park, MD, 20742
J. Berger
Affiliation:
Center for Superconductivity Research, Department. of Physics, University of Maryland, College Park, MD, 20742
S. Dhar
Affiliation:
Center for Superconductivity Research, Department. of Physics, University of Maryland, College Park, MD, 20742
K.S. Chang
Affiliation:
Center for Superconductivity Research, Department. of Physics, University of Maryland, College Park, MD, 20742
T. Venkatesan
Affiliation:
Center for Superconductivity Research, Department. of Physics, University of Maryland, College Park, MD, 20742
T.C. Loughran
Affiliation:
Department of Electrical and Computer Engineering, University of Maryland, College Park, MD, 20742
R.D. Vispute
Affiliation:
Blue Wave Semiconductors Inc., 6208 Three Apple Downs, Columbia, MD, 21045
S.N. Yedave
Affiliation:
Blue Wave Semiconductors Inc., 6208 Three Apple Downs, Columbia, MD, 21045
Get access

Abstract

In this paper we present the accelerated reliability testing of MgZnO based UV detectors. The UV detectors are fabricated on glass, quartz and sapphire substrates by Pulsed Laser Deposition (PLD) technique. The films are highly oriented and show sharp transmission at 350nm and 330nm for Mg composition of 10% and 20% in ZnO, respectively. The device response has been studied and life expectancy of the devices has been estimated from the accelerated tests.

Type
Research Article
Copyright
Copyright © Materials Research Society 2004

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

[1] Brennan, K.F., Haralson, J., Parks, J.F., Salem, A., Microelectronics Reliability 39, 1873 (1999)10.1016/S0026-2714(99)00197-3Google Scholar
[2] Bagnall, D.M., Chen, Y.F., Zhu, Z., Yao, T., Koyama, S., Shen, H., and Goto, T., Appl. Phys. Lett. 70, 2230 (1997)10.1063/1.118824Google Scholar
[3] Ohtomo, A., Kawasaki, M., Sakurai, Y., Yoshida, Y., Koinuma, H., Yu, P., Tang, Z.K., Wong, G. K., and Segawa, Y., Mater. Sci. Eng., B 54, 24 (1998)10.1016/S0921-5107(98)00120-2Google Scholar
[4] Look, D.C., Mater. Sci. Eng., B 80, 383 (2001)10.1016/S0921-5107(00)00604-8Google Scholar
[5] Tang, Z. K., Yu, P., Wong, G. K. L., Kawasaki, M., Ohtomo, A., Koinuma, H., and Segawa, Y., Solid State Commun. 103, 459(1997)10.1016/S0038-1098(97)00254-8Google Scholar
[6] Narayan, J., Sharma, A.K., Kvit, A., Jin, C., Muth, J. F., and Holland, O. W., Solid State Commun. 121, 9 (2002)10.1016/S0038-1098(01)00431-8Google Scholar
[7] Choopun, S., Vispute, R. D., Yang, W., Sharma, R. P., Venkatesan, T., and Shen, H., Appl. Phys. Lett. 80, 1529 (2002)10.1063/1.1456266Google Scholar
[8] Auret, F. D., Goodman, S. A., Hayes, M., Legodi, M. J., van Laarhoven, H. A., and Look, D. C., Appl. Phys. Lett. 79, 3074 (2001)10.1063/1.1415050Google Scholar
[9] Vispute, R.D., Talyansky, V., Choopun, S., Sharma, R. P., and Venkatesan, T. He, M., Tang, X., Halpern, J.B., and Spencer, M. G., Li, Y. X. and Salamanca-Riba, L. G. Iliadis, A. A., Jones, K. A. Appl. Phys. Lett. 73, 348 (1998)10.1063/1.121830Google Scholar
[10] MgZnO based UV detectors on glass, quartz, polyamide substrates: A Comparative study S.S. Hullavarad, R.D. Vispute, I. Takeuchi, T. Venkatesan, To be published.Google Scholar
[11] Yoshida, S. and Suzuki, J., Appl. Phys. Lett 85, 7931 (1998)Google Scholar