No CrossRef data available.
Article contents
Vadose Zone Monitoring System for Site Characterization and Transport Modeling
Published online by Cambridge University Press: 10 February 2011
Abstract
Monitoring the vadose zone below buried waste provides an early warning of contaminate Advanced Tensiometer transport toward the groundwater. To quantify the transport mechanisms, vadose zone hydraulic characteristics and the physical variables need to be obtained. We have designed and implemented a Vadose Zone Monitoring System (VZMS) to monitor or sample the 3 state variables of the vadose zone, water potential, water content and chemical concentration. The state variables are monitored using an Advanced Tensiometer (AT), a borehole water content sensor (BWCS) and a vacuum lysimeter, respectively. This system was installed at the Savannah River Site (SRS) E-Area disposal site, where low level wastes have been disposed of in shallow trenches. The system has operated for The system has operated for several months providing nearly continuous water content and water potential data. The vacuum lysimeters were activated on a quarterly schedule. Installation details and an example data set are presented to illustrate the effectiveness of the VZMS, and demonstrate the utility of the VZMS as an indicator of contaminant transport.
- Type
- Research Article
- Information
- Copyright
- Copyright © Materials Research Society 2000