Hostname: page-component-586b7cd67f-l7hp2 Total loading time: 0 Render date: 2024-11-29T07:50:45.350Z Has data issue: false hasContentIssue false

Phenomenological Model of Non-Evaporated Getter for Micro-electromechanical Systems (MEMS) Applications

Published online by Cambridge University Press:  17 March 2011

Caroline A. Kondoleon
Affiliation:
Electronics Packaging and Prototyping Division, The Charles Stark Draper Laboratory, Inc., Cambridge, MA 02139
Thomas F. Marinis
Affiliation:
Electronics Packaging and Prototyping Division, The Charles Stark Draper Laboratory, Inc., Cambridge, MA 02139
Get access

Abstract

There has been increasing interest in the development and use of micro-electromechanical systems (MEMS) for various applications. Some MEM devices such as gyroscopes, accelerometers and bolometers, must be sealed under vacuum, at pressures below 10 millitorr, for efficient operation. A gas absorbing material (getter) is placed in the packages of these devices, to help maintain vacuum levels over service lives of many years. Heating under vacuum, just prior to sealing the package, activates getter, of this type. This study was undertaken to develop a model that could be used to estimate the quantity of getter needed as well as optimize the activation process subject to process constraints on time and temperature.

The material studied was a titanium and zirconium-based alloy (7:3 by weight) non-evaporable getter in the form of strips produced by SAES Getters. The zirconium alloy consisted of zirconium (70.0%), vanadium (24.6%) and iron (5.4%) by weight. The getter was analyzed under different ambient conditions of temperature, time and atmospheric pressure. Auger electron spectroscopy (AES) depth profiling was used to analyze the diffusion depth of the contaminant gases absorbed by the getter material under each condition. The data acquired from the depth profiles were fit to a simple diffusion model. This model is currently being validated, by activating the getter material under various ambient conditions, and measuring pressures and gas compositions inside packages using a residual gas analyzer (RGA). The utility of this model for optimization of getter activation and estimating package vacuum levels over time will be discussed.

Type
Research Article
Copyright
Copyright © Materials Research Society 2001

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Marinis, T.F., Fulginiti, D.A. and Clausen, H.G., Packaging MEM Sensor Arrays, Proceedings of 1999 Fall Materials Research Society Conference. Boston, Massachusetts, Nov. (1999).Google Scholar
2. Mohanty, Rita and Li, Jacob, Use of Getters In Hermetic Packages, Vacuum Technology and Coating. 40, Oct. (2000).Google Scholar
3. Barosi, A. and Giorgi, T., Vacuum. 23(1), 15 (1972).Google Scholar
4. Kreyszig, E., Advanced Engineering Mathematics. New York: John Wiley and Sons, Inc., 1993.Google Scholar
5. Crank, J., The Mathematics of Diffusion. London: Oxford University Press, 1975.Google Scholar
6. Callister, W., Materials Science and Engineering: An Introduction. New York: John Wiley and Sons, Inc., 1997.Google Scholar