Hostname: page-component-586b7cd67f-2plfb Total loading time: 0 Render date: 2024-11-23T11:33:42.837Z Has data issue: false hasContentIssue false

Optimization of low-k UV Curing: Effect of Wavelength on Critical Properties of the Dielectrics

Published online by Cambridge University Press:  31 January 2011

German Aksenov
Affiliation:
[email protected], IMEC, Leuven, Belgium
David De Roest
Affiliation:
[email protected], IMEC, Leuven, Belgium
Patrick Verdonck
Affiliation:
[email protected], ASM Belgium, Leuven, Belgium
Premysl Marsik
Affiliation:
[email protected], Masaryk University, Brno, Czech Republic
Denis Shamiryan
Affiliation:
[email protected], IMEC, Leuven, Belgium
Mikhail R Baklanov
Affiliation:
[email protected], IMEC, Leuven, Belgium
Get access

Abstract

The results of recent investigations show that after UV curing of CVD SiCOH low-k films deposited with organic material (porogen) some amount of the porogen remains in the cured films in the form of non-volatile graphitized phase, known as “porogen residue”. These residues could influence leakage current and reliability. The goal of the present work is investigation of the different parameters of UV curing that can influence amount of the porogen residue. In this work we focused generally on the study of the amount of porogen residues as function of the wavelength of curing light and the porosity of the material (amount of deposited porogen). To study the curing dependence on the wavelength, we compared optical properties (measured by spectroscopic ellipsometry) and IR adsorption (measured by FTIR) of samples cured by 172 nm monochromatic light (lamp A) with samples cured by broadband source with wavelength more than 200 nm (lamp B). To understand how the amount of porogen residue depends on the amount of deposited porogen (porosity), three films with different k-value were deposited: a film with k = 3 deposited without porogen and two porogen-based low-k with target k-value of 2.5 and 2.3. Furthermore, taking into account that He/H2 plasma effectively removes the porogen residues from porous films without any plasma damage of the matrix material, we exposed the films to that plasma. Then these films were cured by broadband lamp at different temperatures and amount of porogen residues was measured by ellipsometry. It was found that He/H2 plasma cannot fully remove the porogen and causes film shrinkage. The Subsequent UV curing does not produce significant changes.

Type
Research Article
Copyright
Copyright © Materials Research Society 2009

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1 Marsik, P., et al., PSSc, 5, 12531256, (2008).Google Scholar
2 Eslava, S., et al., Journal of the Electrochemical Society 155, G115–G120 (2008).Google Scholar
3 Prager, L. et al., Microelectronic Engineering 85, 20942097 (2008).Google Scholar
4 Walle, C. G. Van de, Physica B 376(1-6), (2006).Google Scholar
5 Kassavetis, S., et al., Diamond and Related Materials 16, 18131822 (2007).Google Scholar
6 Urbanowicz, A., et al., Proc. Of Advanced Metallization Conference, 2022 Sep. 2009, San Diego, USA Google Scholar