Abstract

In this paper, we proposed a novel miniaturized cell stretching tool using an Ionic Polymer-Metal Composites (IPMC) actuator. An IPMC is small, light weight and can be fabricated in any shape. And it drives flexibly like a living thing by low voltage. In this study, the PDMS chamber with PDMS membrane of 20 μEm thick for cell culturing had been fabricated on IPMC. And cultured cells were stretched by IPMC. The displacements of PDMS membrane were measured by a laser displacement sensor. And then, cells were cultured on PDMS membrane and stretched them by the motion of IPMC in an incubator. The results show that the PDMS membrane and cells were stretched by IPMC. This is the first fabrication of a cell stretching tool using IPMC. The potentiality of cell stretching tool using IPMC was demonstrated.

Type
Research Article
Copyright
Copyright © Materials Research Society 2008

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1 Morishima, K., Tanaka, Y., Ebara, M., Shimizu, T., Kikuchi, A., Yamato, M., Okano, T. and Kitamori, T., “Demonstration of a bio-microactuator powered by cultured cardiomyocytes coupled to hydrogel micropillars”, Sensors & Actuators: B. Chemical, 119(1), 345350, (2006).Google Scholar
2 Tanaka, Y., Morishima, K., Shimizu, T., Kikuchi, A., Yamato, M., Okano, T., Kitamori, T., “Demonstration of a PDMS-based bio-microactuator using cultured cardiomyocytes to drive polymer micropillars”, Lab on a Chip, 6(2), 230235, (2006).Google Scholar
3http://www.strex.jp/Google Scholar
4 Shuxiang, Guo and Kinji, Asaka, “A New Type of Micropump Driven by A low Electric Voltage”, Acta Mechanica Sinica, Vol.20, No.2, April 2004, pp146151.Google Scholar
5 Shahinpoor, Mohsen, “Ionic Polymer-conductor composites as biomimetic sensors, robotic actuators and artificial musclesa review”, Electrochinica Acta 48, pp23432353, (2003).Google Scholar
6 Feng, Guo-Hua and Chen, Ri-Hong, “Fabrication and characterization of arbitrary shaped ìIPMC transducers for accurately controlled biomedical applications”, Sensors and Actuators, A physical, (2007).Google Scholar
7 Kada, Kenji, Yasui, Kenji, Naruse, Keiji, Kamiya, Kaichiro, Kodama, Itsuo and JunjiToyama, Orientation Change of Cardiocytes Induced by Cyclic Stretch Stimulation: Time Dependency and Involvement of Protein Kinases”, J Mol Cell Cardiol 31, pp247259, (1999).Google Scholar