Hostname: page-component-586b7cd67f-dsjbd Total loading time: 0 Render date: 2024-11-23T12:01:55.274Z Has data issue: false hasContentIssue false

Improved Fabrication Technique for Microstructured Solid-State Neutron Detectors

Published online by Cambridge University Press:  31 January 2011

Steven L Bellinger
Affiliation:
[email protected], Kansas State University, Mechanical and Nuclear Engineering, Manhattan, Kansas, United States
Walter J McNeil
Affiliation:
[email protected], Kansas State University, Mechanical and Nuclear Engineering, Manhattan, Kansas, United States
Douglas Scott McGregor
Affiliation:
[email protected], Kansas State University, Mechanical and Nuclear Engineering, Manhattan, Kansas, United States
Get access

Abstract

Microstructured semiconductor neutron detectors have superior efficiency performance over thin-film coated planar semiconductor detectors. The microstructured detectors have patterns deeply etched into the semiconductor substrates subsequently backfilled with neutron reactive materials. The detectors operate as pn junction diodes. Two variations of the diodes have been fabricated, which either have a rectifying pn junction selectively formed around the etched microstructures or have pn junctions conformally diffused inside the microstructures. The devices with the pn junctions formed in the perforations have lower leakage currents and better signal formation than the devices with selective pn junctions around the etched patterns. Further, pulse height spectra from conformally diffused detectors have the main features predicted by theoretical models, whereas pulse height spectra from the selectively diffused detectors generally do not show these features. The improved performance of the conformal devices is attributed to stronger and more uniform electric fields in the detector active region. Also, system noise, which is directly related to leakage current, has been dramatically reduced as a result of the conformal diffusion fabrication technique. A sinusoidal patterned device with 100 μm deep perforations backfilled with 6LiF was determined to have 11.9 ± 0.078% intrinsic detection efficiency for 0.0253 eV neutrons, as calibrated with thin-film planar semiconductor devices and a 3He proportional counter.

Type
Research Article
Copyright
Copyright © Materials Research Society 2009

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Shultis, J. K. and McGregor, D. S. IEEE Trans. Nucl. Sci. NS-53, 16591665 (2006).Google Scholar
2. McGregor, D. S. Klann, R. T. Gersch, H. K. Ariesanti, E. Sanders, J. D. and VanDerElzen, B. IEEE Trans. Nucl. Sci., NS-49, 19992004 (2002).Google Scholar
3. McNeil, W. J. Bellinger, S. L. Unruh, T. C. Patterson, E. L. Shultis, J. K. and McGregor, D. S. (IEEE NSS Conf. Record, San Diego, CA, 2006) pp. 37323735.Google Scholar
4. Bellinger, S.L. McNeil, W.J. Unruh, T.C. McGregor, D.S. IEEE Trans. Nucl. Sci. (2009) (in press).Google Scholar
5. Bellinger, S.L. McNeil, W.J. Unruh, T.C. McGregor, D.S. (IEEE NSS Conf. Record, Waikiki, HI, 2007) pp. 19041907.Google Scholar
6. Uher, J. Fröjdh, C., Jakùbek, J., Kenney, C. Kohout, Z. Linhart, V. Parker, S. Petersson, S. Pospíŝil, S., Thungström, G., Nucl. Instrum. Meth. A576, 3237 (2007).Google Scholar
7. Nikolic, R. J. Conway, A. M. Reinhardt, C. E. Graff, R. T. Wang, T. F. Deo, N. and Cheung, C. L. (IEEE NSS Conf. Record, Waikiki, HI, 2007), pp. 15771580.Google Scholar
8. McGregor, D.S. Bellinger, S.L. Bruno, D. Cowley, S.A. Dunn, W.L. Elazegui, M. Kargar, A. McNeil, W.J. Oyenan, H. Patterson, E. Shultis, J.K. Singh, G. Solomon, C.J. Unruh, T.C. (IEEE NSS Conf. Record, Waikiki, HI, 2007) pp. 808812.Google Scholar
9. Rice, B. Inductively Coupled Plasma Etching of Silicon and Gallium Arsenide, (MS thesis, Kansas State University, 2003).Google Scholar
10. Clarkson, J.P. Sun, W. Hirschman, K. D. Gadeken, L. L. Fauchet, P. M., Phys. Stat. Sol. (a) 5, 15361540 (2007).Google Scholar
11. McGregor, D.S. McNeil, W. J. Bellinger, S. L. Unruh, T. C. Shultis, J. K. Nucl. Instrum. Meth. (2009) (in review).Google Scholar
12. Shultis, J.K. and McGregor, D.S. Nucl. Instrum. and Meth. (2009) (in press).Google Scholar