Fabrication of Piezoelectric Ceramic / Polymer Composite Transducers using Fused Deposition of Ceramics

Published online by Cambridge University Press:  10 February 2011

G. M. Lous
Affiliation:
Ceramic and Materials Engineering Department, Rutgers, the State University of New Jersey, NJ 08854
I. A. Cornejo
Affiliation:
Ceramic and Materials Engineering Department, Rutgers, the State University of New Jersey, NJ 08854
T. F. McNulty
Affiliation:
Ceramic and Materials Engineering Department, Rutgers, the State University of New Jersey, NJ 08854
A. Safari
Affiliation:
Ceramic and Materials Engineering Department, Rutgers, the State University of New Jersey, NJ 08854
S. C. Danfortha
Affiliation:
Ceramic and Materials Engineering Department, Rutgers, the State University of New Jersey, NJ 08854
Get access

Abstract

The Fused Deposition of Ceramics (FDC) technique was used to fabricate ceramic skeletons for development of piezoelectric composite transducers for medical imaging. The green parts were designed in order to have 30 vol% of PZT-5H ceramic in the final composites. Physical characterization of the sintered samples revealed that 96% of the theoretical density was achieved. Optical microscopy showed that defects, such as small roads and bubbles were eliminated due to powder processing improvements. The electromechanical properties of the final composites were found to be similar to properties obtained for conventionally made composites.

Type
Research Article
Copyright
Copyright © Materials Research Society 1999

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

[1] Gururaja, T.R., Safari, A., Newnham, R.E. and Cross, L.E., in Electronic Ceramics, edited by Levinson, L.M., (Marcel Dekker, Inc, New York, 1987), p 93145.Google Scholar
[2] Janas, V.F. and Safari, A., J. Am. Ceram. Soc., 78 (11), 29452955 (1995).Google Scholar
[3] Danforth, S.C., Safari, A., Agarwala, M., Bandyopadhyay, A., Weeren, R. van, Langrana, N. and Jamalabad, V., U.S. Patent No. 5 738 817 (14 April 1998).Google Scholar
[4] Bandyopadhyay, A., Panda, R.K., Janas, V.F., Agarwala, M.K., Weeren, R. van, Danforth, S.C., Safari, A., ISAF Proceedings, 2, 9991002 (1996).Google Scholar
[5] Bandyopadhyay, A., Panda, R.K., McNulty, T.F., Mohammadi, F., Danforth, S.C., Safari, A., Rapid Prototyping Journal, 4 (1), 3749 (1998).Google Scholar
[6] Hall, D.D.N., Bennett, J.T. and Hayward, G., SPIE, 1733, 216227 (1992).Google Scholar
[7] Smith, W.A. and Auld, B.A., IEEE Trans. On UFFC, 38 (1), 4047 (1991).Google Scholar
[8] Newnham, R.E., Skinner, D.P., Cross, L.E., Mat. Res. Bull., 13, 525536 (1978).Google Scholar
[9] Smith, W.A., ISAF Proceedings, 1990, 145152.Google Scholar
[10] Wicks, J.D. and Howe, K.S., Fundamentals of the Ultrasonographic Technique, (Yearbook Medical Publishers, Chicago, 1983), p 2353.Google Scholar
[11] McNulty, T.F., Mohammadi, F., Bandyopadhyay, A., Shanefield, D.J., Danforth, S.C. and Safari, A., Rapid Prototyping Journal, in Press.Google Scholar