Exciton Dynamics in Ultrathin InAs/GaAs Quantum-Wells

Published online by Cambridge University Press:  15 February 2011

J. Brübach
Affiliation:
COBRA Interuniversity Research Institute, Eindhoven University of Technology, Department of Physics, P.O. Box 513, 5600 MB Eindhoven, The Netherlands
J. E. M. Haverkort
Affiliation:
COBRA Interuniversity Research Institute, Eindhoven University of Technology, Department of Physics, P.O. Box 513, 5600 MB Eindhoven, The Netherlands
J. H. Wolter
Affiliation:
COBRA Interuniversity Research Institute, Eindhoven University of Technology, Department of Physics, P.O. Box 513, 5600 MB Eindhoven, The Netherlands
P. D. Wang
Affiliation:
Nanoelectronics Research Centre, Department of Electronics and Electrical Engineering, University of Glasgow, Glasgow G12 8QQ, United Kingdom
N. N. Ledentsov
Affiliation:
Nanoelectronics Research Centre, Department of Electronics and Electrical Engineering, University of Glasgow, Glasgow G12 8QQ, United Kingdom
C. M. Sotomayor Torres
Affiliation:
Nanoelectronics Research Centre, Department of Electronics and Electrical Engineering, University of Glasgow, Glasgow G12 8QQ, United Kingdom
Get access

Abstract

We have studied the transient behaviour of a sharp emission line, which emerges close to the heavy-hole (hh) exciton photoluminescence line in a 1.6 monolayer thick InAs layer embedded in a GaAs matrix, when the light-hole (lh) exciton transition is excited. We find, that the decaytime of the sharp line is equal to the lh-exciton lifetime for excitation on resonance, but it strongly decreases for excitation off resonance. Since in our structure the energy separation between the hhand lh-exciton transitions amount to one GaAs LO phonon we conclude, that the sharp line originates from double resonant Raman scattering for off resonant excitation, whereas it is predominantly due to resonant luminescence for excitation on resonance. The strong decrease of the intensity of the sharp line due to a temperature rise from 4 to 18K proves the existence of a well confined lh-exciton state. In addition, we performed carrier capture measurements on this structure. We find a constant capture time of 20ps at the lh-exciton transition, whereas the capture time decreases step-like from 55ps to 22ps within the hh-exciton transition. This provides clear evidence for a two-step capture process, where the lh-level acts as an intermediate capture state.

Type
Research Article
Copyright
Copyright © Materials Research Society 1996

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

[1] Cingolani, R., Brandt, O., Tapfer, L., Scarmaccio, G., LaRocca, G.C., and Ploog, K., Phys. Rev. B 42, 3209 (1990)Google Scholar
[2] Wang, P.D., Ledentsov, N.N., Torres, C.M. Sotomayor, Kop'ev, P.S., and Ustinov, V.M., Appl. Phys. Lett. 64, 1526 (1994)Google Scholar
[3] Klein, M.V., Phys. Rev. B 8, 919 (1973)Google Scholar
[4] Kleinman, D.A., Miller, R.C., and Gossard, A.C., Phys. Rev. B 35, 664 (1987)Google Scholar
[5] Miller, R.C., Kleinman, D.A., Tu, C.W., and Sputz, S.K., Phys. Rev. B 34, 7444 (1986)Google Scholar
[6] Shen, Y.R., Phys. Rev. B 9, 622 (1974)Google Scholar
[7] Stanley, R., Hegarty, , Fischer, R., Feldmann, J., Göbel, E.O., Feldman, R.D., and Austin, R.F., Phys. Rev. Lett. 67, 128 (1991)Google Scholar
[8] Brandt, O., Tapfer, L., Cingolani, R., Ploog, K., Hohenstein, M., and Phillipp, F., Phys. Rev. B 41, 12599 (1991)Google Scholar