Hostname: page-component-586b7cd67f-t8hqh Total loading time: 0 Render date: 2024-11-23T14:57:50.006Z Has data issue: false hasContentIssue false

DEMUX SiC optical transducers for fluorescent proteins detection

Published online by Cambridge University Press:  07 July 2011

M. Vieira
Affiliation:
Electronics Telecommunication and Computer Dept. ISEL, R. Conselheiro Emídio Navarro, 1949-014 Lisboa, PortugalTel: +351 21 8317290, Fax: +351 21 8317114, [email protected] CTS-UNINOVA, Quinta da Torre, Monte da Caparica, 2829-516, Caparica, Portugal. DEE-FCT-UNL, Quinta da Torre, Monte da Caparica, 2829-516, Caparica, Portugal
P. Louro
Affiliation:
Electronics Telecommunication and Computer Dept. ISEL, R. Conselheiro Emídio Navarro, 1949-014 Lisboa, PortugalTel: +351 21 8317290, Fax: +351 21 8317114, [email protected] CTS-UNINOVA, Quinta da Torre, Monte da Caparica, 2829-516, Caparica, Portugal.
M. A. Vieira
Affiliation:
Electronics Telecommunication and Computer Dept. ISEL, R. Conselheiro Emídio Navarro, 1949-014 Lisboa, PortugalTel: +351 21 8317290, Fax: +351 21 8317114, [email protected] CTS-UNINOVA, Quinta da Torre, Monte da Caparica, 2829-516, Caparica, Portugal.
M. Fernandes
Affiliation:
Electronics Telecommunication and Computer Dept. ISEL, R. Conselheiro Emídio Navarro, 1949-014 Lisboa, PortugalTel: +351 21 8317290, Fax: +351 21 8317114, [email protected] CTS-UNINOVA, Quinta da Torre, Monte da Caparica, 2829-516, Caparica, Portugal.
J. Costa
Affiliation:
Electronics Telecommunication and Computer Dept. ISEL, R. Conselheiro Emídio Navarro, 1949-014 Lisboa, PortugalTel: +351 21 8317290, Fax: +351 21 8317114, [email protected] CTS-UNINOVA, Quinta da Torre, Monte da Caparica, 2829-516, Caparica, Portugal.
Get access

Abstract

This paper presents results on the optimization of multilayered a-SiC:H heterostructures that can be used as an optical transducer for fluorescent proteins detection. Stacked structures composed by p-i-n based a-SiC:H cells are used as wavelength selective devices, in the visible range. The transfer characteristics of the transducers are studied both theoretically and experimentally under several wavelength illuminations corresponding to different fluorophores and tested for a proper fine tuning in the violet, cyan and yellow wavelengths. The devices were characterized through spectral response measurements under different electrical and optical bias conditions and excitation frequencies. Results show that the output waveform is balanced by the wavelength and frequency of each input fluorescent signal, keeping the memory of the wavelength and intensity of the incoming optical carriers. To selectively recover a single wavelength a specific voltage or optical bias is applied.

Type
Research Article
Copyright
Copyright © Materials Research Society 2011

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

[1] LaVan, D.A, Terry McGuire, Robert Langer, Nat. Biotechnol. 21(10), 2003, 11841191.Google Scholar
[2] Grace, D., Medical Product Manufacturing News, 12, 2008, 2223.Google Scholar
[3] Vieira, M., Fantoni, A., Fernandes, M., Louro, P., Lavareda, G., Carvalho, C. N., Journal of Nanoscience and Nanotechnology, Vol. 9,, Number 7, July 2009, pp. 40224027(6).Google Scholar
[4] Louro, P., Vieira, M., Vygranenko, Yu., Fantoni, A., Fernandes, M., Lavareda, G., Carvalho, N., Mat. Res. Soc. Symp. Proc., 989 (2007) A12.04.Google Scholar
[5] Vieira, M., Fantoni, A., Louro, P., Fernandes, M., Schwarz, R., Lavareda, G., and Carvalho, C. N., Vacuum, Vol. 82, Issue 12, 8 August 2008, pp: 15121516.Google Scholar
[6] Jovin, T.M. and Arndt-Jovin, D.J. FRET microscopy: Digital imaging of fluorescence resonance energy transfer. Application in cell biology. In Cell Structure and Function by Microspectrofluometry, Kohen, E., Hirschberg, J. G. and Ploem, J. S.. London: Academic Press, 1989. pp. 99117.Google Scholar