No CrossRef data available.
Article contents
A Comparative Assessment of Tru Waste Forms and Immobilization Processes*
Published online by Cambridge University Press: 15 February 2011
Abstract
Six alternative TRU waste forms and seven waste immobilization processes are comparatively assessed on the basis of both product properties and process costs and risks. The waste forms are characterized for their leachability, mechanical strength, and thermal and radiation stability. The processes are evaluated in terms of costs (for processing, transportation, and repository disposal) and in terms of occupational exposure, industrial hazard, and quality assurance. Cast cement is recommended for immobilization of defense TRU wastes. A glass system, either borosilicate or aluminosilicate, is recommended for immobilization of commercial TRU wastes.
- Type
- Research Article
- Information
- Copyright
- Copyright © Materials Research Society 1982
Footnotes
Operated for the U.S. Department of Energy by Battelle Memorial Institute.
Work supported by the U.S. Department of Energy under Contract DE–AC06–76RLO 1830.