Hostname: page-component-78c5997874-j824f Total loading time: 0 Render date: 2024-11-06T01:07:51.302Z Has data issue: false hasContentIssue false

Reusable Surface Molecular Imprint Biosensors Aided by Naturally Occurring Surface Roughness Indices for Point-of-Care Diagnostics

Published online by Cambridge University Press:  19 February 2019

Yehoshua Auerbach
Affiliation:
Lawrence High School, Cedarhurst, NY;
Rebecca Isseroff*
Affiliation:
Lawrence High School, Cedarhurst, NY;
Nicholas Clayton
Affiliation:
Stony Brook University, Stony Brook, NY;
Miguel Hulyalkar
Affiliation:
South Side High School, Rockville Center, NY;
Andrew Todt
Affiliation:
Lake Oswego High School, Lake Oswego, OR
Vincent Ricotta
Affiliation:
Stony Brook University, Stony Brook, NY;
Miriam Rafailovich
Affiliation:
Stony Brook University, Stony Brook, NY;
*
Get access

Abstract

We have shown that molecular imprinting (MI) technology can be used to produce sensitive, robust, cost-effective biosensing systems with a real-time electrochemical readout that can be utilized for point of care diagnostics. Real time detection of biomarkers is essential when rapid, critical decisions need to be made, such as in situations where public health is threatened. Our biosensor has high sensitivity compared to standard methods like ELISA, and results are obtained within minutes, using inexpensive, accessible potentiometric readout technology. These biosensors utilize surface molecular imprinting of a self-assembling monolayer of hydroxy-terminated alkanethiol chains which form a crystalline ‘lock-and-key’ structure around a target analyte, allowing the sensors to detect and differentiate between bio-macromolecules of similar size and shape with high selectivity and sensitivity. The sensors are extremely versatile and able to detect a diverse range of molecules of varied chemical composition and structure. To fully exploit the sensors’ advantages, especially in remote, economically disadvantaged areas, it is important to quantify their durability and reusability. Biosensor chips were created to test the viability of hemoglobin detection and to evaluate the potential for sensor reusability when washed after detection testing. The successful readsorption of hemoglobin even after washing, accompanied by cyclic voltammetry data indicating the preservation of the SAM, indicate that these biosensors are reusable, significantly augmenting the device’s value. Potential applications include the analysis of complex chemical and biological processes such as stem cell differentiation and on-the-spot detection of diseases such as Zika.

Type
Articles
Copyright
Copyright © Materials Research Society 2019 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

Yu, Y., Zhang, Q., Chang, C.-C., Liu, Y., Yang, Z., Guo, Y., Wang, Y., Galanakis, D.K., Levon, K., and Rafailovich, M., Analyst 141, 5607 (2016).CrossRefGoogle Scholar
Bain, C.D., Troughton, E.B., Tao, Y.T., Evall, J., Whitesides, G.M., and Nuzzo, R.G., J. Am. Chem. Soc. 111, 321 (1989).CrossRefGoogle Scholar
Wang, Y., Zhang, Z., Jain, V., Yi, J., Mueller, S., Sokolov, J., Liu, Z., Levon, K., Rigas, B., and Rafailovich, M.H., Sensors and Actuators B: Chemical 146, 381 (2010).CrossRefGoogle Scholar
Wang, Y., Zhou, Y., Sokolov, J., Rigas, B., Levon, K., and Rafailovich, M., Biosens. Bioelectron. 24, 162 (2008).CrossRefGoogle Scholar
Mathur, A., Blais, S., Goparaju, C.M.V., Neubert, T., Pass, H., and Levon, K., PLoS ONE 8, (2013).CrossRefGoogle Scholar
Yu, Y., Zhang, Q., Buscaglia, J., Chang, C.-C., Liu, Y., Yang, Z., Guo, Y., Wang, Y., Levon, K., and Rafailovich, M., Analyst 141, 4424 (2016).CrossRefGoogle Scholar