Hostname: page-component-586b7cd67f-2plfb Total loading time: 0 Render date: 2024-11-22T20:59:25.128Z Has data issue: false hasContentIssue false

Optical Waveguide Biosensors for Highly Sensitive and High-Throughput Applications

Published online by Cambridge University Press:  28 March 2016

Ikuo Uematsu*
Affiliation:
Department of Organic and Polymeric Materials, Tokyo Institute of Technology, Mail Box S8-27, 2-12-1 Ookayama, Meguro-ku, Tokyo 152-8552, Japan Corporate Manufacturing Engineering Center, Toshiba Corporation, 33 Shin-Isogo-Cho, Isogo-ku, Yokohama 235-0017, Japan
Ichiro Tohno
Affiliation:
Corporate Manufacturing Engineering Center, Toshiba Corporation, 33 Shin-Isogo-Cho, Isogo-ku, Yokohama 235-0017, Japan
Shingo Kasai
Affiliation:
Corporate Manufacturing Engineering Center, Toshiba Corporation, 33 Shin-Isogo-Cho, Isogo-ku, Yokohama 235-0017, Japan
Masaaki Hirakawa
Affiliation:
Corporate Manufacturing Engineering Center, Toshiba Corporation, 33 Shin-Isogo-Cho, Isogo-ku, Yokohama 235-0017, Japan
Kayoko Omiya
Affiliation:
Corporate Manufacturing Engineering Center, Toshiba Corporation, 33 Shin-Isogo-Cho, Isogo-ku, Yokohama 235-0017, Japan
Hidetoshi Matsumoto
Affiliation:
Department of Organic and Polymeric Materials, Tokyo Institute of Technology, Mail Box S8-27, 2-12-1 Ookayama, Meguro-ku, Tokyo 152-8552, Japan
*
Get access

Abstract

In the present study, highly sensitive and high-throughput optical waveguide biosensors were fabricated by using the sensing membranes containing dye and polymer-enzyme complex. Optical light waveguide can detect the optical change in the vicinity of the guide surface with high sensitivity due to the evanescent wave scattering. The glucose sensing membranes, composed of dye, enzymes, and biocompatible polymers were prepared by solution processing on the optical waveguide. Herein, we used 3, 3’, 5, 5’-tetramethylbenzidine (TMBZ) as a dye, glucose oxidase (GOD) and peroxidase (POD) as enzymes, phosphatide polymer for protection of biological activity of enzyme, and carboxymethyl cellulose (CMC) as a binder. Then we focused on the optimal composition and structure of sensing membranes for the enhancement in the sensitivity and response speed. The developed glucose sensors demonstrated 20 times higher sensitivity than the conventional light waveguide glucose sensors and the low-detection limit of 0.1g/L glucose within the detection time of 60 sec. For further improvement in the sensitivity, microporous sensing membranes were fabricated by using electrospraying technique. The electroprayed sensing membranes gave 40 % higher sensitivity than nonporous sensing membranes. These results show that both the composition and structure of sensing membrane are crucial factors for highly sensitive and high-throughput optical waveguide biosensors.

Type
Articles
Copyright
Copyright © Materials Research Society 2016 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

White, Brandy J., James Hermon, H, Biosensors and Bioelectronics, 20, 19771983 (2005)CrossRefGoogle Scholar
Uematsu, I., Tohno, I. and Omiya, K., JP05060441 (2005)Google Scholar
Tohno, I., Omiya, K., Takase, T., Uematsu, I., JP04377006 (2006)Google Scholar
Kasai, S., Omiya, K., Uematsu, I., Tohno, I., Japanese Unexamined Patent Application Publication No. 2006-153497 (2006)Google Scholar
Uematsu, I., Matsumoto, H., Morota, K., Minagawa, M., Tanioka, A., Yamagata, Y., and Inoue, K., J. Colloid Interface Sci. 269, 336340 (2004)CrossRefGoogle Scholar