Hostname: page-component-586b7cd67f-rcrh6 Total loading time: 0 Render date: 2024-11-22T22:33:47.805Z Has data issue: false hasContentIssue false

MEMS sensor-based monitoring system for engineered geological disposal facilities

Published online by Cambridge University Press:  02 January 2018

Wenbin Yang*
Affiliation:
Department of Civil & Environmental Engineering, University of Strathclyde, Glasgow G1 1XJ, UK
Rebecca Lunn
Affiliation:
Department of Civil & Environmental Engineering, University of Strathclyde, Glasgow G1 1XJ, UK
Alessandro Tarantino
Affiliation:
Department of Civil & Environmental Engineering, University of Strathclyde, Glasgow G1 1XJ, UK
*
Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

The design of a novel MEMS (Micro-Electro-Mechanical System) sensor-based monitoring system is presented in this article for the in situ monitoring of the conditions (temperature, relative humidity) of an engineered bentonite barrier for the underground disposal of radioactive waste in a geological disposal facility (GDF). A first prototype of the monitoring system incorporating multiple state-of-the-art MEMS sensors has been developed on a PCB-based (Printed Circuit Board) structure, in order to measure the variation of temperature and relative humidity inside a cylindrical bentonite block during the hydration process. The monitoring system comprises separate sensor boards, the microcontroller-equipped interface board and the software user interface in the Labview environment. One of the main design priorities is to reduce the size of the embedded sensors in order to minimize their influence on the hydro-mechanical response of the bentonite block. The sensor boards are encapsulated in different manners to protect them from moisture, chemical corrosion and mechanical shocks. The sensor system has been tested and calibrated in the temperature range between –20°C and 120°C, and at different relative humidity levels implemented by saturated salt solutions in enclosed containers. Test results demonstrate that the sensors have shown good functionality and robustness in harsh test environments such as high temperature and high humidity. Both temperature and relative humidity sensors have shown satisfactory precision level and temporal stability, which are in good accordance with the design specification of these devices.

Type
Research Article
Creative Commons
Creative Common License - CCCreative Common License - BY
Copyright © The Mineralogical Society of Great Britain and Ireland 2015. This is an open access article, distributed under the terms of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright
Copyright © The Mineralogical Society of Great Britain and Ireland 2015

References

AITEMIN (2013) State of Art Report on Monitoring Technology. Modern Project WP2 report, 2013.Google Scholar
Akyildiz, I.F., Su, W., Sankarasubramaniam, Y. and Cayirci, E. (2002) Wireless sensor networks: a survey. Computer Networks, 38, 393422.CrossRefGoogle Scholar
Alonso, E.E., Springman, S.M. and Ng, W.W. (2009) Monitoring large-scale tests for nuclear waste disposal. Geotechnical and Geological Engineering, 26, 817826.CrossRefGoogle Scholar
Breen, B.J., Garcia-Sineriz, J.L., Maurer, H., Mayer, S., Schröder, T.J. and Verstricht, J. (2012) EC MoDeRn Project: In-situ demonstration of innovative monitoring technologies for geological disposal. WM2012 Conference. Available at http://www.wmsym.org/archives/2012/papers/12053.pdf Google Scholar
Ceylan, H., Gopalakrishnan, K., Taylor, P., Shrotriya, P., Kim, S., Prokudin, M., Wang, S., Buss, A.F., Zhang, J. et al. (2011) A Feasibility Study on Embedded Micro-electromechanical Sensors and Systems (MEMS) for Monitoring Highway Structures. Iowa Highway Research Board Report No. TR-575.Google Scholar
Chao, N.H., Dispenza, J.A. and DeAngelis, M.E. (2012) Encapsulating protective layers for enhancing surviv-ability of circuit board assemblies in harsh and extreme environments. ASME 2012 International Mechanical Engineering Congress and Exposition, 9, 363373.CrossRefGoogle Scholar
Greenspan, L. (1977) Humidity fixed points of binary aqueous solutions. Journal of research of the national bureau of standards, 81A, 8996.CrossRefGoogle Scholar
Juvankoski, M., Ikonen, K. and Jalonen, T. (2012) Buffer Production Line 2012: Design, Production and Initial State of the Buffer. Posiva report 2012-17.Google Scholar
Lidskog, R. and Andersson, A.C. (2002) The Management of Radioactive Waste: A Description of en Countries. SKB report, ISBN 91-973987-3-X .Google Scholar
NXP® (2014) I2C-bus Specification and User Manual. Rev. 6, 2014. Available from: http://www.nxp.com/documents/user_manual/UM10204.pdf.Google Scholar
Sensirion® Filter Cap SF2 datasheet (2011) Available from: http://www.sensirion.com/sf2/.Google Scholar
Tencer, M. and Moss, J.S. (2002) Humidity management of outdoor electronic equipment: methods, pitfalls, and recommendations. IEEE Transactions on Components and Packaging Technologies, 25, 6672.CrossRefGoogle Scholar
Winston, P.W and Bates, D.H. (1960) Saturated solutions for the control of humidity in biological research. Ecology, 41, 232237.CrossRefGoogle Scholar