Hostname: page-component-78c5997874-fbnjt Total loading time: 0 Render date: 2024-11-09T07:53:04.690Z Has data issue: false hasContentIssue false

Chemical analysis of olivines by the electron microprobe

Published online by Cambridge University Press:  14 March 2018

J. V. Smith
Affiliation:
Department of the Geophysical Sciences, University of Chicago, Chicago 37, Illinois, U.S.A.
R. C. Stenstrom
Affiliation:
Department of the Geophysical Sciences, University of Chicago, Chicago 37, Illinois, U.S.A.

Summary

Thirty-one natural olivines, of which 25 had been previously analysed by wet chemical methods, have been analysed for Mg, Fe, Mn, Ca, Ni, and Co by electron-microprobe techniques. The totals of the olivine molecules Fo, Fa, etc., calculated from the above metals vary from 97·6 to 101·5 with a mean of 99·6%. Twenty-one of the specimens had been used previously by Yoder and Sahama to prepare a determinative curve between mole per cent. Fo and the lattice spacing d130. Yoder and Sahama had found that the data for natural olivines showed large random displacements from a straight line, and that the best straight line deviated for low Fo values from that for synthetic olivines. A plot of Fo determined from the microprobe vs. d130 corrected for lattice expansion caused by Ca and Mn shows no systematic deviation between natural and synthetic specimens, and only small deviations from the best continuous curve (maximum 4% in Fo assuming no error in d130). The maximum contents found for Mn, Ca, Ni, and Co were 3·2, 0·54, 0·33, and 0·03%, respectively. For these minor constituents, some of the wet chemical analyses agreed very well with the microprobe results while others showed large deviations. Although the substitution of Ca is small, it can affect considerably the determination of mole per cent. Fo from d130.

After specimen preparation and calibration have been carried out, microprobe analyses for most major and minor (but not trace) elements in common silicates can be made with an accuracy of about 0·5 to 5% of the amount present in about one minute for each group of three elements. Although standard chemical methods applied to large homogeneous samples will retain their fundamental reference value, microprobe techniques with their high spatial resolution, relative freedom from contamination problems, high speed, and moderate to good accuracy promise to revolutionize analytical programmes in mineralogy and petrology.

Type
Research Article
Copyright
Copyright © The Mineralogical Society of Great Britain and Ireland 1965

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Bilcks, (L.S.), 1963. Electron Probe Microanalysis. Interscience Publishers, New York.Google Scholar
Chudoba, (F.F.) and Frechen, (J.), 1943. Neues Jahrb. Min. Abt. A, p. 91.Google Scholar
Deer, (W.A.), Howie, (R.A.), and Zussman, (J.), 1962. Rock-forming Minerals Ortho- and Ring Silicates. John Wiley, New York.Google Scholar
HäKli, (A.), 1963. Bull. Comm. Geo]. Finlande, no. 209.Google Scholar
Jackson, (E.D.), 1960. U.S. Geol. Surv. Prof. Paper 400B, p. 432.Google Scholar
Jambor, (J.L.) and Smith (C. ]-I.), 1962. Amer. Min., vol. 47, p. 194.Google Scholar
Muir, (I.D.) and Tilley, (C.E.), 1961. J. Geol., vol. 69, p. 186.Google Scholar
Ross, (C.S.), Foster, (M.D.), and M Yers, (A.T.), 1954. Amer. Min., vol. 39, p. 693.Google Scholar
Sahama, (TH. G.), and HytöNen, (K.), 1958. Ibid., vol. 43, p. 862.Google Scholar
Snow, (R.B.), 1943. J. Amer. Cer. Soc., vol. 26, p. 15.Google Scholar
Tilley, (C.E.), 1952. Amer. J. Sci., Bowen vol., p. 529.Google Scholar
Yoder, (H.S.) and Sahama (TH. G.), 1957. Amer. Min., vol. 421-, 475.Google Scholar