Hostname: page-component-586b7cd67f-t8hqh Total loading time: 0 Render date: 2024-11-26T13:28:26.026Z Has data issue: false hasContentIssue false

Effect of nozzle tilting on splashing in jet wiping

Published online by Cambridge University Press:  26 July 2005

Get access

Abstract

A physical limit to the galvanizing speed exists over which the liquid film explodes completely and prevents any further wiping. This limit is presently estimated around 180-200 m/min. A dimensionless approach including the Weber and Reynolds numbers is proposed to be able to predict the occurrence of the phenomenon. Practically it comes out that nozzles tilted by 30° down to the pot can pushback the limit by 30 %. A maximal line speed around 220 m/min could thus be reached.