Hostname: page-component-586b7cd67f-vdxz6 Total loading time: 0 Render date: 2024-11-29T02:11:56.407Z Has data issue: false hasContentIssue false

Caractérisation expérimentale des transferts couplés de chaleuret de masse dans les enveloppes de constructions en bois

Published online by Cambridge University Press:  30 January 2013

Helisoa Rafidiarison
Affiliation:
Universitéde Lorraine, LERMAB, ENSTIB, 27 rue Philippe Séguin, 88051 Épinal, France CRITT BOIS, 27 rue Philippe Séguin, 88051 Épinal, France
Éric Mougel*
Affiliation:
Universitéde Lorraine, LERMAB, ENSTIB, 27 rue Philippe Séguin, 88051 Épinal, France
Alexis Nicolas
Affiliation:
CRITT BOIS, 27 rue Philippe Séguin, 88051 Épinal, France AVEN’R, 2T grande rue, 88460 Faucompierre, France
*
a Auteur pour correspondance :[email protected]
Get access

Abstract

Une double enceinte climatique conçue sur le principe de la méthode de la boîte chaudegardée a été mise au point afin d’étudier en laboratoire le comportement thermique ethygrique de différentes configurations de parois en bois. Le dispositif est dotéd’équipements de régulation lui permettant de reproduire des sollicitations climatiquesstationnaires ou dynamiques proches d’un climat réel et de suivre l’évolution des profilsde température et d’humidité dans les parois testées. Dans ce travail, le suivi ducomportement hygrothermique d’une paroi en ossature bois comportant des matériauxhygroscopiques et soumises à différentes conditions est rapporté. Les résultats ont montréque la capacité du dispositif à bien reproduire les conditions imposées a permis demesurer les propriétés importantes de parois en régime permanent (résistance thermique) ettransitoire (amortissement et déphasage thermique). Les essais réalisés ont également misen évidence le comportement hygroscopique des matériaux testés.

Type
Research Article
Copyright
© AFM, EDP Sciences 2013

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Références

Hameury, S., Moisture buffering capacity of heavy timber structures directly exposed to an indoor climate: a numerical study, Build. Environment40 (2005) 14001412 CrossRefGoogle Scholar
H.M. Kunzel, A. Holm, K. Sedlbauer, F. Antretter, M. Ellinger, Moisture buffering effect of interior linings made from wood or wood based products, Fraunhofer-Institute for Building Physics, IBP Report HTB-04/2004/e, 2004
Osanyintola, O.F., Talukdar, P., Simonson, C.J., Effect of initial conditions, boundary conditions and thickness on the moisture buffering capacity of spruce plywood, Energy Build. 38 (2006) 12831292 CrossRefGoogle Scholar
Osanyintola, O.F., Simonson, C.J., Moisture buffering capacity of hygroscopic building materials: Experimental facilities and energy impact, Energy Build. 38 (2006) 12701282 CrossRefGoogle Scholar
Simonson, C.J., Salonvaara, M., Ojanen, T., Moderating indoor conditions with hygroscopic building materials and outdoor ventilation, ASHRAE NA 110 (2004) 804819 Google Scholar
James, C.Simonson, C.J.Talukdar, P.Roels, S. Numerical and experimental data set for benchmarking hygroscopic buffering models, Int. J. Heat Mass Transf. 53 (2010) 36383654 CrossRefGoogle Scholar
Medjelekh, D., Abdou, S., El Ganaoui, M., Impact of the thermal inertia of material on the hygrothermal comfort of building, Int. Rev. Chem. Eng. 2 (2010) 391397 Google Scholar
Asan, H., Effects of wall’s insulation thickness and position on time lag and decrement factor, Energy Build. 28 (1998) 299305 CrossRefGoogle Scholar
Asan, H., Numerical computation of time lags and decrement factors for different building materials, Build. Environment 41 (2006) 615620 CrossRefGoogle Scholar
Ghazi Wakili, K., Tanner, Ch., U-value of a dried wall made of perforated porous clay bricks – Hot box measurement versus numerical analysis, Energy Build. 35 (2003) 675680 CrossRefGoogle Scholar
Nussbaumer, T.,Ghazi Wakili Ch, K.. Tanner, Experimental and numerical investigation of the thermal performance of a protected vacuum insulation system applied to a concrete wall, Appl. Energy 83 (2006) 841855 CrossRefGoogle Scholar
Rose, J., Svendsen, S., Validating numerical calculations against guarded hot box measurements, Nordic J. Build. Phys. 4 (2004) 9 Google Scholar
Kalamees, T., Vinha, J., Hygrothermal calculations and laboratory tests on timber-framed wall structures, Build. Environment 38 (2003) 689697 CrossRefGoogle Scholar
Pavlik, Z., Cerny, R., Experimental assessment of hygrothermal performance of an interior thermal insulation system using a laboratory technique simulating on-site conditions, Energy Build. 40 (2008) 673678 CrossRefGoogle Scholar
NF EN ISO 8990, Isolation thermique – Détermination des propriétés de transmission thermique en régime stationnaire, Méthodes à la boîte chaude gardée et calibrée, 2006