Hostname: page-component-586b7cd67f-dlnhk Total loading time: 0 Render date: 2024-11-26T22:13:43.398Z Has data issue: false hasContentIssue false

XUV interferometry using high-order harmonics: Application to plasma diagnostics

Published online by Cambridge University Press:  30 July 2001

J.-F. HERGOTT
Affiliation:
Service des Photons, Atomes et Molécules, CEA-DSM-DRECAM, Centre de Saclay, 91191 Gif-sur-Yvette, France
P. SALIÈRES
Affiliation:
Service des Photons, Atomes et Molécules, CEA-DSM-DRECAM, Centre de Saclay, 91191 Gif-sur-Yvette, France
H. MERDJI
Affiliation:
Service des Photons, Atomes et Molécules, CEA-DSM-DRECAM, Centre de Saclay, 91191 Gif-sur-Yvette, France
L. LE DÉROFF
Affiliation:
Service des Photons, Atomes et Molécules, CEA-DSM-DRECAM, Centre de Saclay, 91191 Gif-sur-Yvette, France
B. CARRÉ
Affiliation:
Service des Photons, Atomes et Molécules, CEA-DSM-DRECAM, Centre de Saclay, 91191 Gif-sur-Yvette, France
T. AUGUSTE
Affiliation:
Service des Photons, Atomes et Molécules, CEA-DSM-DRECAM, Centre de Saclay, 91191 Gif-sur-Yvette, France
P. MONOT
Affiliation:
Service des Photons, Atomes et Molécules, CEA-DSM-DRECAM, Centre de Saclay, 91191 Gif-sur-Yvette, France
P. D'OLIVEIRA
Affiliation:
Service des Photons, Atomes et Molécules, CEA-DSM-DRECAM, Centre de Saclay, 91191 Gif-sur-Yvette, France
D. DESCAMPS
Affiliation:
Department of Physics, Lund Institute of Technology, P.O. Box 118, S-221 00 Lund, Sweden
J. NORIN
Affiliation:
Department of Physics, Lund Institute of Technology, P.O. Box 118, S-221 00 Lund, Sweden
C. LYNGÅ
Affiliation:
Department of Physics, Lund Institute of Technology, P.O. Box 118, S-221 00 Lund, Sweden
A. L'HUILLIER
Affiliation:
Department of Physics, Lund Institute of Technology, P.O. Box 118, S-221 00 Lund, Sweden
C.-G. WAHLSTRÖM
Affiliation:
Department of Physics, Lund Institute of Technology, P.O. Box 118, S-221 00 Lund, Sweden
M. BELLINI
Affiliation:
L.E.N.S., Largo E. Fermi, 2, I-50125 Florence, Italy
S. HULLER
Affiliation:
Centre de Physique Théorique, CNRS, Ecole Polytechnique, 91128 Palaiseau, France

Abstract

In this paper, we present and compare the two different XUV interferometric techniques using high-order harmonics that have been developed so far. The first scheme is based on the interference between two spatially separated phase-locked harmonic sources while the second uses two temporally separated harmonic sources. These techniques have been applied to plasma diagnostics in feasibility experiments where electron densities up to a few 1020 e/cm3 have been measured with a temporal resolution of 200 fs. We present the main characteristics of each technique and discuss their respective potentials and limitations.

Type
Research Article
Copyright
© 2001 Cambridge University Press

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)