Hostname: page-component-586b7cd67f-l7hp2 Total loading time: 0 Render date: 2024-11-26T04:29:05.288Z Has data issue: false hasContentIssue false

X-ray diagnostics of almost transparent Fe plasma of inverted corona target

Published online by Cambridge University Press:  01 April 1999

A.V. BESSARAB
Affiliation:
Russian Federal Nuclear Center—All-Russian Research Institute of Experimental Physics, 607190, Sarov, Prospect Mira 37, Nizhny Novgorod Region, Russia
S.A. BEL'KOV
Affiliation:
Russian Federal Nuclear Center—All-Russian Research Institute of Experimental Physics, 607190, Sarov, Prospect Mira 37, Nizhny Novgorod Region, Russia
P.D. GASPARYAN
Affiliation:
Russian Federal Nuclear Center—All-Russian Research Institute of Experimental Physics, 607190, Sarov, Prospect Mira 37, Nizhny Novgorod Region, Russia
N.V. ZHIDKOV
Affiliation:
Russian Federal Nuclear Center—All-Russian Research Institute of Experimental Physics, 607190, Sarov, Prospect Mira 37, Nizhny Novgorod Region, Russia
A.V. KUNIN
Affiliation:
Russian Federal Nuclear Center—All-Russian Research Institute of Experimental Physics, 607190, Sarov, Prospect Mira 37, Nizhny Novgorod Region, Russia
A.V. PINEGIN
Affiliation:
Russian Federal Nuclear Center—All-Russian Research Institute of Experimental Physics, 607190, Sarov, Prospect Mira 37, Nizhny Novgorod Region, Russia
A.N. SUBBOTIN
Affiliation:
Russian Federal Nuclear Center—All-Russian Research Institute of Experimental Physics, 607190, Sarov, Prospect Mira 37, Nizhny Novgorod Region, Russia
N.A. SUSLOV
Affiliation:
Russian Federal Nuclear Center—All-Russian Research Institute of Experimental Physics, 607190, Sarov, Prospect Mira 37, Nizhny Novgorod Region, Russia
V.A. TOKAREV
Affiliation:
Russian Federal Nuclear Center—All-Russian Research Institute of Experimental Physics, 607190, Sarov, Prospect Mira 37, Nizhny Novgorod Region, Russia

Abstract

Measurements of spectral and energy X-ray characteristics of almost transparent Fe plasma produced by laser radiation inside the inverted-corona targets have been made at ISKRA-5 facility. The targets were spherical plastics cavities with 2-mm diameter and 4.6-μm thickness covered from inside with Fe layer 0.25-μm thickness. X-ray spectrum, X-ray total energy, and the energy of a HeαFe resonance line have been measured. Experimental data and calculation results are collated.

Type
Research Article
Copyright
© 1999 Cambridge University Press

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)