Article contents
Improved Phebus laser performances required for precision laser–target experiments
Published online by Cambridge University Press: 15 October 2009
Abstract
The Precision Phebus program, started in 1993, emphasizes a series of laser and target experiment objectives on the two-beam Phebus Nd-phosphate glass laser. Recently, three major objectives that are also very important issues for megajoule-class lasers have been met: First, the balance of the incident beam-to-beam 3ω power is shown to be in the range from 5 to 12% for 3-ns, 3ω-shaped pulses of reproducible high-energy shots; second, the smoothing uniformity of the laser energy deposited on the target, that is, the contrast of the spatial beam modulations, can be kept lower than 5%; and, finally, the tight control of the beam targeting leads to a pointing precision of less than 10 μrd on the target at the target chamber center (TCC) and of 80 μrd on X-ray sources located up to 3 cm from the TCC to improve the space- and time-resolved X-ray shadowgraphy techniques performed for target physics experiments such as implosion and hydrodynamical instability studies.
- Type
- Research Article
- Information
- Copyright
- Copyright © Cambridge University Press 1998
References
REFERENCES
- 1
- Cited by