Hostname: page-component-586b7cd67f-g8jcs Total loading time: 0 Render date: 2024-11-26T18:26:42.329Z Has data issue: false hasContentIssue false

Energy loss and effective charge of low-energy oxygen ions in partially ionized plasma

Published online by Cambridge University Press:  17 May 2001

K. NISHIGORI
Affiliation:
Research Laboratory for Nuclear Reactors, Tokyo Institute of Technology, 2-12-1 O-okayama, Meguro-ku, Tokyo, 152-8550, Japan
U. NEUNER
Affiliation:
Gesellschaft für Schwerionenforshung (GSI), Postfach 110552, D-64220 Darmstadt, Germany
M. TAKIZAWA
Affiliation:
Research Laboratory for Nuclear Reactors, Tokyo Institute of Technology, 2-12-1 O-okayama, Meguro-ku, Tokyo, 152-8550, Japan
M. KOJIMA
Affiliation:
Research Laboratory for Nuclear Reactors, Tokyo Institute of Technology, 2-12-1 O-okayama, Meguro-ku, Tokyo, 152-8550, Japan
T. SAGAMI
Affiliation:
Research Laboratory for Nuclear Reactors, Tokyo Institute of Technology, 2-12-1 O-okayama, Meguro-ku, Tokyo, 152-8550, Japan
A. SAKUMI
Affiliation:
Research Laboratory for Nuclear Reactors, Tokyo Institute of Technology, 2-12-1 O-okayama, Meguro-ku, Tokyo, 152-8550, Japan
J. HASEGAWA
Affiliation:
Research Laboratory for Nuclear Reactors, Tokyo Institute of Technology, 2-12-1 O-okayama, Meguro-ku, Tokyo, 152-8550, Japan
Y. OGURI
Affiliation:
Research Laboratory for Nuclear Reactors, Tokyo Institute of Technology, 2-12-1 O-okayama, Meguro-ku, Tokyo, 152-8550, Japan
M. OGAWA
Affiliation:
Research Laboratory for Nuclear Reactors, Tokyo Institute of Technology, 2-12-1 O-okayama, Meguro-ku, Tokyo, 152-8550, Japan

Abstract

This article reports on the interaction between slow ions and a partially ionized plasma. Temporal evolutions of energy loss and charge distribution of 2.4 MeV oxygen beams in the laser-induced polyethylene plasma were measured. The charge distribution showed strong stripping ability in the early phase of the plasma. Stopping power deduced from the experimental energy loss was 1.9 times larger than that for the solid. The effective charge of the projectile ion was estimated from the yields of 4+ and 6+ states. The peak value of the effective charge was 1.4 times larger than that of the solid. The stopping power equation given by Sigmund was extended for the partially ionized plasma and it could reproduce the measured energy loss.

Type
Research Article
Copyright
© 2000 Cambridge University Press

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)