Published online by Cambridge University Press: 30 July 2018
Intensity-modulated radiation therapy (IMRT) is one of the most reported techniques for head and neck cancer treatment, as it allows a good coverage of the planning target volume (PTV) while sparing the surrounding organs at risk (OAR) better than conventional conformal radiotherapy. The objective of this work is to optimise an IMRT technique for the simultaneously integrated boost (SIB) treatment of larynx cancer delivering a total dose of 69·96 Gy to the boost volume and 54·45 Gy to the elective volume in 33 fractions.
Three IMRT techniques, each using seven equally spaced beams, were planned for a sample of 10 patients. The first two techniques (IMRT-0 and IMRT-26) differ only for the starting angle of the seven beams, whereas the third (IMRT-CT) combines both these techniques by delivering IMRT-0 in the first half of treatment, and IMRT-26 in the second half, thus taking advantage of using 14 beams in total while using seven at a time only. The planning results were compared according to the dose coverage, homogeneity and conformity of the two PTVs, as well as to the dose to OARs, that is, spinal cord, parotids, mandible, brainstem and healthy tissue (defined as the body volume minus the sum of PTVs).
Basically the PTV coverage resulted acceptable and comparable with all the three techniques. Concerning OARs, statistically better results are obtained in IMRT-CT when compared with IMRT-26 and IMRT-0.
The IMRT-CT technique, combining two different seven-beam setups, delivered in two treatment phases, improves dose distribution without increasing delivery time.
To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
Find out more about the Kindle Personal Document Service.
To save this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you used this feature, you will be asked to authorise Cambridge Core to connect with your Dropbox account. Find out more about saving content to Dropbox.
To save this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you used this feature, you will be asked to authorise Cambridge Core to connect with your Google Drive account. Find out more about saving content to Google Drive.