Hostname: page-component-78c5997874-4rdpn Total loading time: 0 Render date: 2024-11-05T15:15:06.875Z Has data issue: false hasContentIssue false

Optical thickness corrections to ECE measurement of electron temperature in IR-T1 tokamak

Published online by Cambridge University Press:  26 November 2012

MONA AHMADI
Affiliation:
Department of Physics, Mashhad Branch, Islamic Azad University, Mashhad, Iran ([email protected])
PEJMAN KHORSHID
Affiliation:
Department of Physics, Mashhad Branch, Islamic Azad University, Mashhad, Iran ([email protected])
OMID JALILI
Affiliation:
Department of Physics, Noor Branch, Islamic Azad University, Noor, Iran

Abstract

The Electron Cyclotron Emission (ECE) radiation has been investigated, passing through plasma column with concerning absorption effect on the IR-T1 tokamak. The intensity of second harmonic X-mode is used to investigate changes in electron temperature profile. The results show that radiation temperature (Trad) detected outside the plasma column is less than the electron temperature (Te) in the core. The radiation temperature can be directly interpreted as Te to about 3–10% reduction. This implies that optical thickness and electron density effects are more considerable at lower temperatures.

Type
Papers
Copyright
Copyright © Cambridge University Press 2012 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Albajor, F., Bornatici, M., Cortes, G., Dies, J., Engelmann, F., Garcia, J. and Izquierdo, J. 2005 Importance of electron cyclotron wave energy transport in ITER. Nucl. Fusion 45, 642648.CrossRefGoogle Scholar
Bornatici, M., Cano, R., De Barbieri, O. and Engelmann, F. 1983 Electron cyclotron emission and absorption in fusion plasmas. Nucl. Fusion 23, 11531257.CrossRefGoogle Scholar
Bornatici, M., Engelmann, F., Novak, S. and Peterillo, V. 1981 Absorption of plasma of finite density around the electron cyclotron harmonics. Plasma Phys. 23, 11271142.CrossRefGoogle Scholar
Boyd, T. J. M. and Sanderson, J. J. 2003 The Physics of Plasmas, London: Cambridge University.CrossRefGoogle Scholar
Fonseca, A. M. M., Silva, R. P.De GalvÃO, R. M. O., Kuznetzov, Yu. K., Elizondo, J. I., Calderon, E. R., Ruchko, L. F. and Vuolo, J. H. 2004 Electron density measurements from right-hand cutoff ECE in the TCABR tokmak. Braz. J. Phys. 34, 17801785.CrossRefGoogle Scholar
Hartfuss, H. J. and HÄse, M. 2004 Comparison of different methods of electron cyclotron emission-correlation radiometry for the measurement of temperature fluctuation in the plasma core. Rev. Sci. Instrum. 75, 31773184.Google Scholar
Janicki, C. 1993 Electron temperature measurement from the ECE diagnostic in tokamak plasmas under transient conditions. Nucl. Fusion 33, 513515.CrossRefGoogle Scholar
Jun, W., Xiaoyuan, X., Yizhi, W., Changxuan, Y., Baonian, W., Luhmann, N. C., Jian, W. and Zhengang, X. 2006 One-dimensional vertical ECEI diagnostic for HT-7 tokamak. Plasma Sci. Technol. 8, 7679.CrossRefGoogle Scholar
Khorshid, P. 1994 Measurement of electron temperature by ECE system in IR-T1 tokamak, Master's thesis, Islamic Azad University, North Tehran Branch, Tehran.Google Scholar
Pandya, H. K. B., Jani, K. K. and Aditya team 2007 Thermal electron cyclotron emission measurement on the ADITYA tokamk by radiometers. Plasma Phys. Control. Fusion 49, 18091831.CrossRefGoogle Scholar
Peters, M., Gorini, G. & Mantica, P. 1995 Optical thickness corrections to transient ECE temperature measurements in tokamak and stellarator plasma. Nucl. Fusion 35, 873875.CrossRefGoogle Scholar
Silva, R. P.Da, Fonseca, A. M. M., Vuolo, J. H., Calderon, E. R., GalvÃO, R. M. O., Kuznetzov, Yu. K., Raffaelli, J. C. and the TCABR team 2004 ECE radiation in the TCABR tokamak. Braz. J. Phys. 34, 17711779.CrossRefGoogle Scholar