Hostname: page-component-78c5997874-fbnjt Total loading time: 0 Render date: 2024-11-19T02:14:30.314Z Has data issue: false hasContentIssue false

Rapid structural and chemical characterization of ternary phase diagrams using synchrotron radiation

Published online by Cambridge University Press:  03 March 2011

E. D. Specht*
Affiliation:
Metals and Ceramics Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831
A. Rar
Affiliation:
Metals and Ceramics Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 and Department of Materials Science and Engineering, University of Tennessee, Knoxville, Tennessee 37996
G. M. Pharr
Affiliation:
Metals and Ceramics Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 and Department of Materials Science and Engineering, University of Tennessee, Knoxville, Tennessee 37996
E. P. George
Affiliation:
Metals and Ceramics Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 and Department of Materials Science and Engineering, University of Tennessee, Knoxville, Tennessee 37996
P. Zschack
Affiliation:
Frederick Seitz Materials Research Laboratory, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801
H. Hong
Affiliation:
Frederick Seitz Materials Research Laboratory, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801
J. Ilavsky
Affiliation:
National Institute of Standards and Technology, Gaithersburg, Maryland 20899
*
a)Address all correspondence to this author. e-mail: [email protected]
Get access

Abstract

A technique based on synchrotron radiation was developed that allows for rapid structural and chemical characterization of ternary alloys over a wide range of composition. The technique was applied to isothermal sections of the Cr–Fe–Ni system grown on Al2O3(0001) sapphire substrates by sequential deposition of layers of graded.thickness followed by annealing to interdiffuse the elements. A film spanning the Cr–Fe–Ni ternary system was measured in 4 h at a resolution of 2 at.% by rastering the sample under a focused beam of synchrotron radiation while simultaneously measuring the diffraction pattern with a charge-coupled device detector to determine crystallographic phases, texture, and lattice parameters and also measuring the x-ray fluorescence with an energy-dispersive detector to determine elemental composition. Maps of phase composition and lattice parameter as a function of composition for several annealing treatments were found to be consistent with equilibrium values. The technique will be useful in combinatorial materials design.

Type
Articles
Copyright
Copyright © Materials Research Society 2003

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1.Xiang, X.D., Annu. Rev. Mater. Sci. 29, 149 (1999).CrossRefGoogle Scholar
2.McFarland, E.W. and Weinberg, W.H., Trends Biotechnol. 17, 107 (1999).CrossRefGoogle Scholar
3.Zhao, J.C., Jackson, M.R., Peluso, L.A., and Brewer, L.N., MRS Bull. 27(4), 324 (2002).CrossRefGoogle Scholar
4.Yoo, Y.K. and Tsui, F., MRS Bull. 27(4), 316 (2002).CrossRefGoogle Scholar
5.Fukumura, T., Ohtani, M., Kawasaki, M., Okimoto, Y., Kageyama, T., Koida, T., Hasegawa, T., Tokura, Y., and Koinuma, H., Appl. Phys. Lett. 77, 3426 (2000).CrossRefGoogle Scholar
6.Yoo, Y.K., Duewer, F., Fukumura, T., Yang, H.T., Yi, D., Liu, S., Chang, H.Y., Hasegawa, T., Kawasaki, M., Koinuma, H., and Xiang, X., Phys. Rev. B 6322, 224421 (2001).Google Scholar
7.Yoo, Y.K., Ohnishi, T., Wang, G., Duewer, F., Xiang, X.D., Chu, Y.S., Mancini, D.C., Li, Y.Q., and O'Handley, R.C., Intermetallics 9, 541 (2001).CrossRefGoogle Scholar
8.Zhao, J.C., J. Mater. Res. 16, 1565 (2001).CrossRefGoogle Scholar
9.Isaacs, E.D., Marcus, M., Aeppli, G., Xiang, X-D., Sun, X-D., Schultz, P., Kao, H-K., Cargill, G.S., and Haushalter, R., Appl. Phys. Lett. 73, 1820 (1998).CrossRefGoogle Scholar
10.Campbell, C.E., Boettinger, W.J., and Kattner, U.R., Acta Mater. 50, 775 (2002).CrossRefGoogle Scholar
11.Jönsson, B., ISIJ Int. 35, 1415 (1995).CrossRefGoogle Scholar
12.Rar, A., Specht, E.D., Pharr, G.M., and George, E.P. (unpublished).Google Scholar
13.McMaster, W.H., Kerr, N. Del Grande, Mallett, J.H., and Hubbell, J.H., Compilation of X-Ray Cross Sections Report No. UCRL-50174-SEC 2-R-1, (University of California, Livermore, CA, 1969).Google Scholar
14.Hammersley, A.P., FIT20 V10.3 Reference Manual V4.0, ESRF Internal Report No. ESRF98HA01T (ESRF, Grenoble, France, 1998).Google Scholar
15.Hammersley, A.P., Svensson, S.O., Hanfland, M., Fitch, A.N., and Häusermann, D., High Press. Res. 14, 235 (1996).CrossRefGoogle Scholar
16.Hammersley, A.P. and Riekel, C., Synchrotron Radiation News 2, 24 (1989).CrossRefGoogle Scholar
17.Chuang, Y-Y. and Chang, Y.Y., Metall. Trans. A 18, 733 (1987).CrossRefGoogle Scholar
18.Rees, W.P., Burns, B.D., and Cook, A.J., J. Iron Steel Inst. 162, 325 (1949).Google Scholar