Hostname: page-component-586b7cd67f-r5fsc Total loading time: 0 Render date: 2024-11-22T15:10:47.806Z Has data issue: false hasContentIssue false

Cochlear orientation: pre-operative evaluation and intra-operative significance

Published online by Cambridge University Press:  18 July 2018

S Sharma
Affiliation:
Department of Otorhinolaryngology and Head Neck Surgery, Sawai Man Singh Medical College and Hospital, Jaipur, Rajasthan, India
M Grover*
Affiliation:
Department of Otorhinolaryngology and Head Neck Surgery, Sawai Man Singh Medical College and Hospital, Jaipur, Rajasthan, India
S N Singh
Affiliation:
Department of Otorhinolaryngology and Head Neck Surgery, Sawai Man Singh Medical College and Hospital, Jaipur, Rajasthan, India
T Kataria
Affiliation:
Department of Otorhinolaryngology and Head Neck Surgery, Sawai Man Singh Medical College and Hospital, Jaipur, Rajasthan, India
R S Lakhawat
Affiliation:
Department of Otorhinolaryngology and Head Neck Surgery, Sawai Man Singh Medical College and Hospital, Jaipur, Rajasthan, India
*
Address for correspondence: Dr Mohnish Grover, Department of Otorhinolaryngology and Head Neck Surgery, SMS Medical College and Hospital, Jaipur – 302004, Rajasthan, India E-mail: [email protected]

Abstract

Objective

The study primarily aimed to calculate the orientation of the cochlea pre-operatively, using high-resolution computed tomography of the temporal bone, and predict the ease of electrode insertion.

Methods

Pre-operatively, high-resolution computed tomography scans were conducted on children scheduled for cochlear implantation, and two angles, α and β, were calculated. The values of α and β were then correlated with intra-operative difficulty in insertion of the electrode array.

Results

Ninety-six children were included in the study. Of the seven patients who had an α angle of less than 50 degrees, the surgeon experienced difficulties in electrode insertion. However, there were four patients with an α angle of more than 50 degrees for whom the surgeon also experienced difficulties in electrode insertion. In all these patients, the β angle was more than 20 degrees.

Conclusion

Calculation of cochlear orientation and its angle with the surgical axis (α and β) can aid the planning of surgery, particularly with regard to the cochleostomy site and preservation of residual hearing.

Type
Main Articles
Copyright
Copyright © JLO (1984) Limited, 2018 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Footnotes

Dr M Grover takes responsibility for the integrity of the content of the paper

References

1Spoor, CF. The Comparative Morphology and Phylogeny of the Human Bony Labyrinth. Utrecht: Utrecht University, 1993Google Scholar
2Jeffery, N, Spoor, F. Prenatal growth and development of the modern human labyrinth. J Anat 2004;204:7192CrossRefGoogle ScholarPubMed
3Lloyd, SK, Kasbekar, AV, Kenway, B, Prevost, T, Hockman, M, Beale, T et al. Developmental changes in cochlear orientation – implications for cochlear implantation. Otol Neurotol 2010;31:902–7CrossRefGoogle ScholarPubMed
4Kennedy, DW. Multichannel intracochlear electrodes: mechanism of insertion trauma. Laryngoscope 1987;97:42–9CrossRefGoogle ScholarPubMed
5Li, PM, Wang, H, Northrop, C, Merchant, SN, Nadol, JB Jr. Anatomy of the round window and hook region of the cochlea with implications for cochlear implantation and other endocochlear surgical procedures. Otol Neurotol 2007;28:641–8CrossRefGoogle ScholarPubMed
6Briggs, RJ, Tykocinski, M, Stidham, K, Roberson, JB. Cochleostomy site: implications for electrode placement and hearing preservation. Acta Otolaryngol 2005;125:870–6CrossRefGoogle ScholarPubMed
7Adunka, O, Unkelbach, MH, Mack, M, Hambek, M, Gstoettner, W, Kiefer, J. Cochlear implantation via the round window membrane minimizes trauma to cochlear structures: a histologically controlled insertion study. Acta Otolaryngol 2004;124:807–12CrossRefGoogle ScholarPubMed
8Balkany, TJ, Cohen, NL, Gantz, BJ. Surgical technique for the CLARION cochlear implant. Ann Otol Rhinol Laryngol Suppl 1999;177:2730CrossRefGoogle ScholarPubMed