Hostname: page-component-cd9895bd7-gvvz8 Total loading time: 0 Render date: 2024-12-24T13:14:23.585Z Has data issue: false hasContentIssue false

Bacterial biofilm adherence to middle-ear ventilation tubes: scanning electron micrograph images and literature review

Published online by Cambridge University Press:  07 June 2007

M Barakate
Affiliation:
University of Sydney, Department of Otolaryngology, Head and Neck Surgery, Children's Hospital Westmead, New South Wales, Australia
E Beckenham
Affiliation:
University of Sydney, Department of Otolaryngology, Head and Neck Surgery, Children's Hospital Westmead, New South Wales, Australia
J Curotta
Affiliation:
University of Sydney, Department of Otolaryngology, Head and Neck Surgery, Children's Hospital Westmead, New South Wales, Australia
M da Cruz
Affiliation:
University of Sydney, Department of Otolaryngology, Head and Neck Surgery, Children's Hospital Westmead, New South Wales, Australia

Abstract

Introduction: The organisms that cause many device-related and other chronic infections actually grow in biofilms in or on these devices. We sought to examine the role of biofilm formation in chronic middle-ear ventilation tube infection.

Case report: Scanning electron micrograph images are presented which demonstrate biofilm on a middle-ear ventilation tube removed from a five-year-old child's chronically discharging ear. A review of the relevant international literature explores the role of biofilms in chronic infection and discusses potential intervention strategies.

Conclusion: Biofilms may be responsible for chronic middle-ear ventilation tube infection that resists treatment with conventional antibiotics.