Hostname: page-component-cd9895bd7-p9bg8 Total loading time: 0 Render date: 2024-12-23T02:49:46.868Z Has data issue: false hasContentIssue false

Stapedotomy using skeeter drill and self-retaining ear canal retractor: a single surgeon's 1000-plus surgical procedure experience

Published online by Cambridge University Press:  09 February 2022

N Vishnu Swaroop Reddy
Affiliation:
Department of Otolaryngology, Head and Neck and Facial Plastic Surgery, Care hospitals, Hyderabad, India
M Sharma*
Affiliation:
Community Health Centre, Nakaha, India
S Shekhar
Affiliation:
ENT Department, Care Hospitals, Hyderabad, India
Priyanka Sharma
Affiliation:
Department of ENT, District Hospital, Lakhimpur Kheri, India
Rushil Narapareddy
Affiliation:
College of Health Solutions, Arizona State University, Phoenix, USA
Punit Sharma
Affiliation:
All India Institute of Medical Sciences, Patna, India
*
Author for correspondence: Dr Manoj Sharma, Department of ENT, Community Health Centre, Block Road, Nakaha, Lakhimpur Kheri, Uttar Pradesh262701, India E-mail: [email protected]

Abstract

Objective

This study aimed to evaluate the long-term hearing outcomes in stapedotomy surgery using skeeter oto-drill and to assess safety in difficult situations.

Method

A retrospective study was conducted with 944 patients who underwent 1007 stapedotomy procedures over 16 years, performed by a single surgeon using a trans-canal approach and a self-retaining ear canal retractor. Hearing thresholds were calculated over four frequencies. Air–bone conduction hearing thresholds were obtained at 1, 5 and 10 years post-operatively and compared to the pre-operative records.

Results

Out of 1007 operated ears with one year follow up, 98.61 per cent of cases showed a negligible air–bone gap of equal to or less than 5 dB, 1.19 per cent of cases showed an air–bone gap equal to or more than 5 dB but less than 10 dB, and only 0.2 per cent of cases showed an air–bone gap of more than 10 dB.

Conclusion

In this study, using skeeter drill with a 0.6 mm diamond burr to make the fenestra was constant in all the cases and one of the safest techniques, showing persistent long-term hearing results.

Type
Main Article
Copyright
Copyright © The Author(s), 2022. Published by Cambridge University Press on behalf of J.L.O. (1984) LIMITED

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Footnotes

Dr Manoj Sharma takes responsibility for the integrity of the content of the paper

References

Chole, R, McKenna, M. Pathophysiology of otosclerosis. Otol Neurotol 2001;22:249–57CrossRefGoogle ScholarPubMed
McKenna, MJ, MS. Disorders of bone. In: Merchant, SS, Nadol, JB Jr, eds. Schuknecht's Pathology of the ear, 3rd edn. Shelton: People's Medical Publishing House, 2010; 716–37Google Scholar
Bergstrøm, L. Assessment and consequence of malformations of the middle ear. Birth Defects 1980;16:217–41Google ScholarPubMed
Briggs, RJ, Luxford, WM. Correction of conductive hearing loss in children. Otolaryngol Clin North Am 1994;27:607–20CrossRefGoogle ScholarPubMed
Stewart, JM, Downs, MP. Congenital conductive hearing loss: the need for early identification and intervention. Pediatrics 1993;91:355–9Google ScholarPubMed
Shea, JJ Jr. Fenestration of the oval window. Ann Otol Rhinol Laryngol 1958;67:932–51CrossRefGoogle ScholarPubMed
Shea, JJ. Symposium on the operation for mobilization of the stapes in otosclerotic deafness. Laryngoscope 1956;66:729–84Google Scholar
House, HP, Hansen, MR, Al Dakhail, AA, House, JW. Stapedectomy versus stapedotomy: comparison of results with long-term follow-up. Laryngoscope 2002;112:2046–50CrossRefGoogle ScholarPubMed
Cheng, HCS, Agrawal, SK, Parnes, LS. Stapedectomy versus stapedotomy. Otolaryngol Clin North Am 2018;51:375–92CrossRefGoogle ScholarPubMed
Aarnisalo, AA, Vasama, JP, Hopsu, E, Ramsay, H. Long-term hearing results after stapes surgery: a 20-year follow-up. Otol Neurotol 2003;24:567–71CrossRefGoogle ScholarPubMed
Cremers, CW, Beusen, JM, Huygen, PL. Hearing gain after stapedotomy, partial platinectomy, or total stapedectomy for otosclerosis. Ann Otol Rhinol Laryngol 1991;100:959–61CrossRefGoogle ScholarPubMed
Vincent, R, Sperling, NM, Oates, J, Jindal, M. Surgical findings and long-term hearing results in 3,050 stapedotomies for primary otosclerosis: a prospective study with the otology-neurotology database. Otol Neurotol 2006;27:S2547CrossRefGoogle ScholarPubMed
Uppal, S, Bajaj, Y, Rustom, I, Coatesworth, AP. Otosclerosis: the aetiopathogenesis of otosclerosis. Int J Clin Pract 2009;63:1526–30CrossRefGoogle ScholarPubMed
Kisilevsky, VE, Dutt, SN, Bailie, NA, Halik, JJ. Hearing results of 1145 stapedotomies evaluated with Amsterdam hearing evaluation plots. J Laryngol Otol 2009;123:730–6CrossRefGoogle ScholarPubMed
Massey, BL, Hillman, TA, Shelton, C. Stapedectomy in congenital stapes fixation: are hearing outcomes poorer? Otolaryngol Head Neck Surg 2006;134:816–8CrossRefGoogle ScholarPubMed
Dornhoffer, JL, Helms, J, Hoehmann, DH. Stapedectomy for congenital fixation of the stapes. Am J Otol 1995;16:382–6Google ScholarPubMed
Sillence, DO, Senn, A, Danks, DM. Genetic heterogeneity in osteogenesis imperfecta. J Med Genet 1979;16:101–16CrossRefGoogle ScholarPubMed
Mukherjee, D, Sadhu, A, Ghakraborty, PK, Saha, AM. Van Der Hoeve syndrome (osteogenesis imperfecta). Indian J Otolaryngol 1989;41:32–3CrossRefGoogle Scholar
Pedersen, U.. Hearing loss in patients with osteogenesis imperfecta a clinical and audiological study of 201 patients. Scand Audiol 1984;13:6774CrossRefGoogle ScholarPubMed
Stewart, EJ, O'Reilly, BF. A clinical and audiological investigation of osteogenesis imperfecta. Clin Otolaryngol Allied Sci 1989;14:509–14CrossRefGoogle ScholarPubMed
Kuurila, K, Kaitila, I, Johansson, R, Grénman, R. Hearing loss in Finnish adults with osteogenesis imperfecta: a nationwide survey. Ann Otol Rhinol Laryngol 2002;111:939–46CrossRefGoogle ScholarPubMed
Pillion, JP, Vernick, D, Shapiro, J. Hearing loss in osteogenesis imperfecta: characteristics and treatment considerations. Genet Res Int 2011;1:983–42Google Scholar
Marchese, MR, Paludetti, G, De Corso, E, Cianfrone, F. Role of stapes surgery in improving hearing loss caused by otosclerosis. J Laryngol Otol 2007;121:438–43CrossRefGoogle ScholarPubMed
Sparano, A, Leonetti, JP, Marzo, S, Kim, H. Effects of stapedectomy on tinnitus in patients with otosclerosis. Int Tinnitus J 2004;10:73–7Google ScholarPubMed
Ayache, D, Earally, F, Elbaz, P. Characteristics and postoperative course of tinnitus in otosclerosis. Otol Neurotol 2003;24:4851CrossRefGoogle ScholarPubMed
Kylén, P, Stjernvall, JE, Arlinger, S. Variables affecting the drill-generated noise levels in ear surgery. Acta Otolaryngol 1977;84:252–9CrossRefGoogle ScholarPubMed
Michaelides, EM, Kartush, JM. Implications of sound levels generated by otologic devices. Otolaryngol Head Neck Surg 2001;125:361–3CrossRefGoogle ScholarPubMed
Alzhrani, F, Mokhatrish, MM, Al-Momani, MO, Alshehri, H, Hagr, A, Garadat, SN. Effectiveness of stapedotomy in improving hearing sensitivity for 53 otosclerotic patients: retrospective review. Ann Saudi Med 2017;37:4955CrossRefGoogle ScholarPubMed
Bauchet, St, Martin, M, Rubinstein, EN, Hirsch, BE. High-frequency sensorineural hearing loss after stapedectomy. Otol Neurotol 2008;29:447–52CrossRefGoogle Scholar
Strömbäck, K, Köbler, S, Rask-Andersen, . High-frequency hearing following stapes surgery. Acta Otolaryngol 2012;132:944–50CrossRefGoogle ScholarPubMed
Shah, V, Ganapathy, H. Factors Affecting the Outcome of Stapes Surgery. Indian J Otolaryngol Head Neck Surg 2017;70:256–61CrossRefGoogle ScholarPubMed
De Souza, C, Glasscock, ME III. Otosclerosis and Stapedectomy. New York: Thieme Medical Publishers, 2004;12Google Scholar