Hostname: page-component-586b7cd67f-dlnhk Total loading time: 0 Render date: 2024-11-23T01:31:32.239Z Has data issue: false hasContentIssue false

Preliminary results on correlation between neural response imaging and ‘most comfortable levels' in cochlear implantation

Published online by Cambridge University Press:  17 February 2006

I Akin
Affiliation:
SB Ankara Dişkapi Training Hospital, 1st ENT Clinic, Ankara, Turkey
G Kuran
Affiliation:
SB Ankara Dişkapi Training Hospital, 1st ENT Clinic, Ankara, Turkey
C Saka
Affiliation:
SB Ankara Dişkapi Training Hospital, 1st ENT Clinic, Ankara, Turkey
M Vural
Affiliation:
SB Ankara Dişkapi Training Hospital, 1st ENT Clinic, Ankara, Turkey

Abstract

During cochlear implantation, precise placement of the cochlear electrodes against the cochlear nerve is one of the most important steps, necessary to enable the patient to be aware of the stimulus from the implanted device. Neural response imaging (NRI) is a new tool which measures the evoked compound action potential generated as a result of electrical stimulation of the cochlea by properly placed electrodes during surgery.

The aim of this study was to examine the correlation between intra-operative NRI recordings and ‘most comfortable levels’ (M levels) measured during standard fitting with the SoundWave fitting software, in cochlear implantation patients. Seven adult subjects were included in the study. The average duration of profound bilateral deafness was seven years (range = 19 years) and the mean age at implantation was 24 years (range = 17–34 years). All subjects underwent implantation and reached the one-month fitting session; one patient reached the two-month fitting session. The intra-operative NRI threshold (tNRI) was observed to be much higher than the first fitting M levels. The tNRI was 203 per cent of the sequential M value and 246 per cent of the paired M value. All but one intra-operative tNRI values were greater than 150 clinical units (CU), and all first fitting M levels were on average below 100 CU. No obvious correlation was found between individual intra-operative tNRI and first fitting M levels. The M levels at one month were much higher than the first fitting M levels, with much more dispersion.

Type
Main Article
Copyright
2006 JLO (1984) Limited

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Footnotes

This study was presented at the 7th European Symposium on Paediatric Cochlear Implantation, Geneva, 2–5 May 2004.