Hostname: page-component-cd9895bd7-fscjk Total loading time: 0 Render date: 2024-12-23T16:16:55.219Z Has data issue: false hasContentIssue false

Objective assessment of learning curves for the Voxel-Man TempoSurg temporal bone surgery computer simulator

Published online by Cambridge University Press:  29 May 2012

R Nash*
Affiliation:
Department of Otolaryngology, Head and Neck Surgery, Northwick Park Hospital, Harrow, UK
R Sykes
Affiliation:
Department of Otolaryngology, Head and Neck Surgery, Northwick Park Hospital, Harrow, UK
A Majithia
Affiliation:
Department of Otolaryngology, Head and Neck Surgery, Northwick Park Hospital, Harrow, UK
A Arora
Affiliation:
Department of Otorhinolaryngology, Head & Neck Surgery, St. Mary's Hospital, Imperial Healthcare NHS Trust, London, UK
A Singh
Affiliation:
Department of Otolaryngology, Head and Neck Surgery, Northwick Park Hospital, Harrow, UK
S Khemani
Affiliation:
Department of ENT, Surrey and Sussex Healthcare NHS Trust, Surrey, UK
*
Address for correspondence: Mr Robert Nash, Department of Otolaryngology, Head and Neck Surgery, Northwick Park Hospital, Watford Road, Harrow HA1 3UJ, UK Fax: +44 (0)208 869 2067 E-mail: [email protected]

Abstract

Introduction:

Simulators are becoming an increasingly important part of surgical training. Temporal bone surgery is one area in which simulators, such as the Voxel-Man TempoSurg simulator, are likely to play a significant role in training. We present learning curve data from novice trainees using this simulator to learn cortical mastoidectomy, exposure of the sigmoid sinus, and exposure of the short process of the incus.

Methods:

We measured the time taken to perform the procedures, the volume of reference bone removed, and the structures damaged during dissection.

Results:

We found improvement in a number of parameters over the course of the study. The overall scores, structural damage scores and time taken improved, to differing degrees, for each task. The volume of reference bone removed remained constant.

Conclusion:

These results indicate that the trainees' efficiency improved as they became more proficient at removing a given volume of reference bone.

Type
Main Articles
Copyright
Copyright © JLO (1984) Limited 2012

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1Chief Medical Officer's Annual Report 2008: Machines, mannikins and polo mints. http://www.dh.gov.uk/en/MediaCentre/Media/DH_096278 [Accessed May 2011]Google Scholar
2Tolsdorffa, B, Petersikb, A, Pflesserb, B, Pommert, A, Tiede, U, Leuwer, R et al. Preoperative simulation of bone drilling in temporal bone surgery. International Journal of Computer Assisted Radiology and Surgery 2007;2(suppl 1):S160–80Google Scholar
3Zirkle, M, David, W, Roberson, DW, Leuwer, R, Dubrowski, A. Using a virtual reality temporal bone simulator to assess otolaryngology trainees. Laryngoscope 2007;117:258–63CrossRefGoogle ScholarPubMed
4Haque, S, Srinivasan, S. A meta-analysis of the training effectiveness of virtual reality surgical simulators. IEEE Trans Inf Technol Biomed 2006;10:51–8Google Scholar
5Arora, H, Uribe, J, Ralph, W, Zeltsan, M, Cuellar, H, Gallagher, A et al. Assessment of construct validity of the endoscopic sinus surgery simulator. Arch Otolaryngol Head Neck Surg 2005;131:217–21CrossRefGoogle ScholarPubMed
6Aggarwal, R, Crochet, P, Dias, A, Misra, A, Ziprin, P, Darzi, A. Development of a virtual reality training curriculum for laparoscopic cholecystectomy. Br J Surg 2009;96:1086–93Google Scholar
7Ferlitsch, A, Glauninger, P, Gupper, A, Schillinger, M, Haefner, M, Gangl, A et al. Evaluation of a virtual endoscopy simulator for training in gastrointestinal endoscopy. Endoscopy 2002;34:698702Google Scholar
8Zhao, YC, Kennedy, G, Hall, R, O'Leary, S. Differentiating levels of surgical experience on a virtual reality temporal bone simulator. Otolaryngol Head Neck Surg 2010;143 (suppl 3):S30–5Google Scholar
9O'Leary, SJ, Hutchins, MA, Stevenson, DR, Gunn, C, Krumpholz, A, Kennedy, G et al. Validation of a networked virtual reality simulation of temporal bone surgery. Laryngoscope 2008;118:1040–6CrossRefGoogle ScholarPubMed
10Reddy-Kolanu, G, Alderson, D. Evaluating the effectiveness of the Voxel-Man TempoSurg virtual reality simulator in facilitating learning mastoid surgery. Ann R Coll Surg Engl 2011;93:205–8Google Scholar
11Khemani, S, Rennie, C, Singh, A, Tolley, N. Validation of a virtual reality temporal bone simulator. Otolaryngol Head Neck Surg 2010;143:S108CrossRefGoogle Scholar
12Arora, A, Khemani, S, Tolley, N, Singh, A, Budge, J, Varela, DA et al. Face and content validation of a virtual reality temporal bone simulator. Otolaryngol Head Neck Surg 2012;146:497–503Google Scholar
13McDonald, S, Alderson, D, Powles, J. Assessment of ENT registrars using a virtual reality mastoid surgery simulator. J Laryngol Otol 2009;123:e14Google Scholar
14VOXEL-MAN Tempo simulator. In: http://www.voxel-man.de/simulator/temposurg/ [Accessed May 2011]Google Scholar
15Pflesser, B, Petersik, A, Tiede, U, Hohne, KH, Leuwer, R. Volume cutting for virtual petrous bone surgery. Computer Aided Surgery 2002;7:7483CrossRefGoogle ScholarPubMed
16Twomey, PJ, Kroll, MH. How to use linear regression and correlation in quantitative method comparison studies. Int J Clin Pract 2008;62:529–38CrossRefGoogle ScholarPubMed
17Agus, M, Giachetti, A, Gobbetti, E, Zanetti, G, Zorcolo, A, Picasso, B et al. A haptic model of a bone-cutting burr. Stud Health Technol Inform 2003;94:410Google Scholar