Hostname: page-component-586b7cd67f-vdxz6 Total loading time: 0 Render date: 2024-11-23T10:29:03.206Z Has data issue: false hasContentIssue false

Ionomeric bone cement in neuro-otological surgery

Published online by Cambridge University Press:  29 June 2007

Richard T. Ramsden*
Affiliation:
Departments of Otolaryngology, Manchester Royal Infirmary, Oxford Road, Manchester M13 9WL.
Rory C. D. Herdman
Affiliation:
Departments of Otolaryngology, Manchester Royal Infirmary, Oxford Road, Manchester M13 9WL.
Richard H. Lye
Affiliation:
Departments of Neurosurgery, Manchester Royal Infirmary, Oxford Road, Manchester M13 9WL.
*
Department of Otolaryngology, Manchester Royal Infirmary, Oxford Road, Manchester M13 9WL.

Abstract

The use of a polymaleinate glass ionomer cement in 80 neuro-otology cases is described. It has pf oved of great value in translabyrinthine acoustic neuroma surgery, reducing the incidence of CSF fistula to nil. It is the method of choice for fixation of the Nucleus cochlear implant, and has many other applications in the field of otology and neuro-otology. It is easy to use and appears to have no side effects.

Type
Main Articles
Copyright
Copyright © JLO (1984) Limited 1992

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Babighian, G. (1992) Use of glass ionomer cement in otological surgery. A preliminary report. Journal of Laryngology and Otology, 106, 000000.Google Scholar
Brook, I. M.Craig, G. T., Lamb, D. J. (1991) In vitro interaction between primary bone organ cultures, glass ionomer cements and hydroxyapatite/tricalcium phosphate ceramics. Biomaterials, 12, 179186.CrossRefGoogle ScholarPubMed
Dutton, J. E. M., Ramsden, R. X.Lye, R. H., Morris, K., Keith, A. O., Page, J., Vafadis, J. (1991) Acoustic neuroma (schwannoma) surgery 1978–1990. Journal of Laryngology and Otology, 105, 165173.Google Scholar
Geyer, G., Helms, J. (1990) Reconstructive measures in the middle ear and mastoid using a biocompatible cement—Preliminary clinical experience. Clinical Implant Materials, Advances in Biomaterials, 9, 529535.Google Scholar
Hatton, P. V., Craig, G. T., Brook, I. M. (1991) Characterization of the interface between bone and glass ionomer (polyalkenoate) cement using transmission electron microscopy and XRay microanalysis. Paper presented at the European Conference on Biomaterials. Chester, UK.Google Scholar
Jonck, L. M., Grobbelaar, C. J., Strating, H. (1989a) Biological evaluation of glass ionomer cement (Ketac-O) as an interface material in total joint replacement. A screening test. Clinical Materials, 4, 201224.Google Scholar
Jonck, L. M., Grobbelaar, C. J., Strating, H. (1989b) The biocompatibility of glass ionomer cement in joint replacement: bulk testing. Clinical Materials, 4, 85107.Google Scholar
Powis, D. R., Folleras, T., Merson, S. A., Wilson, A. D. (1982) Improved adhesion of a glass-ionomer cement to dentine and enamel. Journal of Dental Research, 61, 14161422.Google Scholar
Wilson, A. D., Kent, B. E. (1972) The glass-ionomer cement: A new translucent dental filling material. Journal of Applied Chemistry and Biotechnology, 21: 313CrossRefGoogle Scholar