Hostname: page-component-586b7cd67f-2plfb Total loading time: 0 Render date: 2024-11-26T10:10:58.166Z Has data issue: false hasContentIssue false

First auditory brainstem implant in the Czech Republic

Published online by Cambridge University Press:  08 March 2006

E. Zverina
Affiliation:
Department of Otorhinolaryngology, Head and Neck Surgery, The First Medical Faculty, Charles University in Prague, Institute for Postgraduate Medical Education, Faculty Hospital Motol, Czech Republic
W.-P. Sollmann
Affiliation:
Department of Neurosurgery, University of Braunschweig, Braunschweig, Germany
J. Betka
Affiliation:
Department of Otorhinolaryngology, Head and Neck Surgery, The First Medical Faculty, Charles University in Prague, Institute for Postgraduate Medical Education, Faculty Hospital Motol, Czech Republic
J. Skrivan
Affiliation:
Department of Otorhinolaryngology, Head and Neck Surgery, The First Medical Faculty, Charles University in Prague, Institute for Postgraduate Medical Education, Faculty Hospital Motol, Czech Republic
T. Tichý
Affiliation:
Laboratory of Electronic Sensory Substitutions, Faculty of Electrotechnics, Czech Technical University, Prague, Czech Republic
B. Nevison
Affiliation:
Cochlear Corporation, London, UK
D. Urgosík
Affiliation:
Department of Stereotactic Radiosurgery, Na Homolce Hospital, Prague, Czech Republic

Abstract

In the Czech Republic, the first implantation of a stimulation electrode into the brainstem was performed on 11 January 1999 in the Department of ORL, Head and Neck Surgery, The First Medical Faculty, Charles University in Prague, University Hospital Motol. The selected patient was a 40-year-old woman with neurofibromatosis type 2 (NF2) who had previously undergone bilateral vestibular schwannoma surgery. Both tumours had been radically removed, the left-sided tumour in 1987, the right-sided one in 1988. She had been completely deaf since the last operation, i.e., for 11 years. The surgery was realized by the international cooperation of three teams. Placement of the electrode pad of the Nucleus CI21+1M system on the ventral and dorsal cochlear nuclei was performed. Electrically evoked auditory brainstem responses (EABRs) proved the correct position of the electrode array. The post-operative course was uneventful. Six weeks after the surgery the patient received her speech processor. Since that time, the patient already absolved several sessions of a speech processor tune-up. She uses the device as an aid in lip-reading. No adverse or pathological side effects have been observed. The patient was the 45th person in Europe to receive an ABI and the first in the Czech Republic.

Type
Research Article
Copyright
Royal Society of Medicine Press Limited 2000

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)