Hostname: page-component-586b7cd67f-t8hqh Total loading time: 0 Render date: 2024-11-26T15:14:19.247Z Has data issue: false hasContentIssue false

Common canalicular obstruction secondary to the use of Herrick lacrimal plugs, requiring endoscopic dacryocystorhinostomy

Published online by Cambridge University Press:  09 June 2008

L Dolan*
Affiliation:
Department of Ophthalmology, Ninewells Hospital and Medical School, Dundee, Scotland, UK
C J MacEwen
Affiliation:
Department of Ophthalmology, Ninewells Hospital and Medical School, Dundee, Scotland, UK
P White
Affiliation:
Department of Otolaryngology, Ninewells Hospital and Medical School, Dundee, Scotland, UK
*
Address for correspondence: Dr Lynne Dolan, Ninewells Hospital and Medical School, Dundee DD1 9SY, Scotland, UK. Fax: 01382 632893 E-mail: [email protected]

Abstract

We report the case of a 40-year-old woman who developed left common canalicular obstruction following insertion of a lacrimal plug. The patient underwent endoscopic dacryocystorhinostomy, revealing the presence of the lacrimal plug occluding the common canaliculus. The patient experienced symptomatic improvement of her epiphora post-operatively.

Type
Clinical Records
Copyright
Copyright © JLO (1984) Limited 2008

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1 Jones, CE, Anklesaria, M, Gordon, AD, Prouty, RE, Rashid, R, Singla, RK et al. Retrospective safety study of the Herrick lacrimal plug: a device used to occlude the lacrimal canaliculus. CLAO J 2002;28:206–10Google Scholar
2 White, WL, Bartley, GB, Hawes, MJ, Linberg, JV, Leventer, DB. Iatrogenic complications related to the use of Herrick lacrimal plugs. Ophthalmology 2001;108:1835–7Google Scholar
3 Gerding, H, Küppers, J, Busse, H. Symptomatic cicatrizial occlusion of canaliculi after insertion of Herrick lacrimal plugs. Am J Ophthalmol 2003;136:926–8Google Scholar
4 Lee, J, Flanagan, JC. Complications associated with silicone intracanalicular plugs. Ophthalmic Plast Reconstr Surg 2001;17:465–9Google Scholar