Another reason for intra-operative imaging during cochlear implantation

Published online by Cambridge University Press:  08 March 2017

M Viccaro*
Affiliation:
ENT Department, University “La Sapienza” of Rome, Italy
E De Seta
Affiliation:
ENT Department, University “La Sapienza” of Rome, Italy
E Covelli
Affiliation:
ENT Department, University “La Sapienza” of Rome, Italy
V Marvaso
Affiliation:
ENT Department, University “La Sapienza” of Rome, Italy
R Filipo
Affiliation:
ENT Department, University “La Sapienza” of Rome, Italy
*
Address for correspondence: Dr M Viccaro, University ‘La Sapienza’ Rome, Viale dell Universita n 31, 00161 Rome, Italy. Fax: 06 4454864 E-mail: [email protected]

Abstract

Objective:

We report a case of a rare cochlear implant complication: the introduction of the electrode array into the superior semicircular canal, with intra-operative measurements of neural response reactions suggesting reasonable functioning of the implant.

Case report:

A two-year old patient affected by congenital, profound, sensorineural deafness underwent bilateral cochlear implantation at the ENT clinic of the ‘La Sapienza’ University of Rome. Two Clarion 90k devices were implanted, and electrophysiological and radiological checks were performed. After the introduction of the array in the right side, neural response imaging was performed, and a neural potential was found only on two apical electrodes, at a stimulation intensity of 431 clinical units. The situation differed on the left side, where neural response imaging was present at a stimulation intensity of 300 clinical units on the two electrodes tested (one apical electrode (number three), and one middle electrode (number nine)). Intra-operative radiological assessment with a transorbital plain films was performed as usual in order to assess the position of the electrodes inside the cochlea. This radiography showed the electrode array to be in the superior semicircular canal in the right ear.

Conclusion:

Intra-operative monitoring tests during cochlear implant surgery play different roles; measurement of impedances and neural response imaging can evaluate the integrity of implant electrodes and the status of the electrode–cochlea interface, but it must not be the sole way in which correct positioning of the array is confirmed. In our opinion, intra-operative radiological assessment is mandatory during cochlear implant surgery.

Type
Online Only Clinical Record
Copyright
Copyright © JLO (1984) Limited 2008

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1 Roland, JT. Complication of cochlear implant surgery. In: Waltzman, SB, Cohen, N, eds. Cochlear Implants. New York: Thieme, 2000;170–7Google Scholar
2 Rotteveel, LJ, Proops, DW, Ramsden, RT, Saeed, SR, Van Olphen, AF, Mylanus, EA. Cochlear implantation in 53 patients with otosclerosis: demographics, computed tomographic scanning, surgery, and complications. Otol Neurotol 2004;25:943–52CrossRefGoogle ScholarPubMed
3 Tange, RA, Grolman, W, Maat, A. Intracochlear misdirected implantation of a cochlear implant. Acta Otolaryngol 2006;126:650–2CrossRefGoogle ScholarPubMed
4 Rosenberg, RA, Cohen, NL, Reede, DL. Radiographic imaging for the cochlear implant. Ann Otol Rhinol Laryngol 1987;96:300–4CrossRefGoogle ScholarPubMed