Hostname: page-component-cd9895bd7-q99xh Total loading time: 0 Render date: 2024-12-24T02:16:45.388Z Has data issue: false hasContentIssue false

Vlf Surface-impedance Measurements for Ice-defth Mapping in the Antarctic

Published online by Cambridge University Press:  20 January 2017

David V. Thiel
Affiliation:
Division of Science and Technology, Griffith University, Nathan, Queensland 4111, Australia
Fiona Neall
Affiliation:
Division of Science and Technology, Griffith University, Nathan, Queensland 4111, Australia
Rights & Permissions [Opens in a new window]

Abstract

VLF surface-impedance measurements were made along four traverses on the Antarctic ice sheet in the vicinity of Casey base. Computer modelling of the surface-impedance data allowed ice-depth predictions to be made; predictions which are almost independent of ice temperature for ice depths less than 800 m. Results agree with ice-radar and other ice-depth data. Surface-impedance anomalies were observed close to moraines and crevasses in the ice sheet. The technique is fast and the instrumentation sufficiently portable for single-person operation.

Type
Research Article
Copyright
Copyright © International Glaciological Society 1989

Introduction

The possiblity of using VLF surface-impedance measurements as an ice-depth probe was first suggested and tested over a temperate glacier in South Island, New Zealand, by Reference ThielThiel (1986). Descriptions of the theory, equipment, method of operation, and data analysis were included in that paper. No independent depth measurements were available on that occasion and so no direct check on the method was available. This paper reports an attempt to verify the procedure on known ice environments in the general area of Casey base, Antarctica, during the summer of 1987–88. A surface-impedance meter capable of operating in a sub-zero temperature environment was constructed following the general principles outlined previously (Reference ThielThiel, 1986). Casey base was used because of the considerable effort that has been made in mapping the adjacent Law Dome by Australian National Antarctic Research Expeditions (ANARE) glaciologists over the last 30 years (Reference BettsBetts, 1981). As with previous instruments, the surface-impedance meter used transmissions from North West Cape (NWC, W.A.) as a radiation source.

Figure 1 illustrates the variation of surface impedance (measured at 22.3 kHz) with ice depth for a number of different ice-electrical parameters (i.e. conductivity and dielectric constant). These characteristics have been found to vary with temperature (Reference ReynoldsReynolds, 1985). Note that for depths of less than approximately 800 m (as was the case in this investigation), the surface impedance is essentially independent of ice temperature.

Vlf Signal Characteristics

It has been known for some time that VLF signals are severely attenuated for propagation across polar ice caps (Reference Westerlund and RederWesterlund and Reder, 1973). As Casey base and NWC lie almost on the same longitude, ice-cap absorption of the signal was negligible. The signal strength at Casey base was approximately the same as that found at Brewster Glacier, New Zealand (Reference ThielThiel, 1986). The great-circle path lengths are 5.6 and 6.2 Mm, respectively, so this is not unexpected.

Short-term fluctuations did require the operator to average 12 readings at each location. This resulted in an error in the surface impedance of approximately 4%. The phase-detector circuit failed to operate throughout field operations. Interpretation of data was therefore only possible using a two-layer method. This precluded the possibility of mapping gravel at the base of the ice (Reference ThielThiel, 1986).

Fig.1. Theoretical plot of surface impedance as a function of ice depth above a rock sub-surface with a conductivity of 1.5 × 10−3 S m−1 and dielectric constant of 15Ɛ0. Three different sets of ice parameters have been used: continuous line, conductivity 3 × 10−6 15Ɛ0 dotted line, conductivity 6.6 × 10−6Sm−1. 15Ɛ0; broken line, conductivity 15Ɛ0.

It is important to note that the signal response is maximized when the electric field antenna (a 10 m insulated wire lying on the surface) is oriented in the direction of the transmitter. Thus, readings were always taken with a north-south orientation. When the traverse direction was west-east, the instrument was re-oriented at each point.

Traverse Results

This paper reports four surface-impedance traverses labelled Tl to T4 conducted close to Casey base, Antarctica, during February-March 1988. The Tl (4 km long) and T2 (1 km long) traverses are shown in Figure 2. Computer modelling was used to convert the surface-impedance data to ice depth and the complex dielectric constants of ice and bedrock. T4, the shortest traverse of 120 m, crossed an isolated crevasse in an attempt to clarify the behaviour of the surface-impedance parameter in the vicinity of crevasses observed previously (Reference ThielThiel, 1986). The other three traverses, Tl, T2, and T3, were undertaken for ice-depth mapping.

The rock/bedrock referred to throughout this paper is predominantly high-grade gneiss with varying concentrations of feldspar, quartz, biotite, and garnet. The concentration of biotite in particular is thought to influence the surface-impedance measurements made on rock platforms.

Fig.2. Map of Casey base environs showing the surface-impedance traverse locations T1—T2.

Tl: Penguin Pass to Sl

The route started from exposed rock to the east of Casey base and continued for 4 km to a survey point designated Si. This line crosses the Loken moraines at a point where they are not clearly exposed at the surface but are evident on the ice-radar profile from 1.4 to 2.4 km. Readings were made every 250 m using a vehicle odometer to determine the distance. Ice conditions during the traverse included almost no snow, somewhat weathered ice to the west of the moraine, and blue ice to the east of the moraine.

The ice-radar result is plotted in Figure 3 along with the ice depth derived from surface-impedance measurements. The depth at Sl is approximately 200 m. The surface-impedance data were converted to ice depth using a simple two-layer model, i.e. ice on bedrock. The following parameters were used: ice conductivity = 6.6 x 10−6Sm−1; ice dielectric constant = 4.5 ॉ0; rock conductivity =1.5 x 10−3Sm−1; rock dielectric constant = 15Ɛ0, where Ɛ0 is the permittivity of free space. The ice parameters, chosen from the −27 °C, 20 kHz data given by Reference ReynoldsReynolds (1985), were thought to be most appropriate to ice conditions at all measurement sites. Uncertainties in ice temperature, bedrock characteristics, and noise in the measurements are estimated to result in a depth-estimate uncertainty of 10%.

Fig.3. T1 ice-depth profile comparison between ice radar (dots) and surface impedance (crosses).

From Figure 3 one can conclude that surface-impedance measurements have penetrated the moraine, whereas the ice radar has mapped the top of the moraine. The rock band is clearly quite steeply dipping, rising from a depth of 120 m to 30 m over a horizontal distance of 600 m. This distinction between ice-radar and surface-impedance measurements is a potentially useful tool in glaciology.

T2: “Jack’s Donga”

Two traverses were made from the outcropped rock close to the sea, across the triple banded moraine towards the Law Dome peak. (The name “Jack’s Donga” refers to a hut located in the area.) An approximate altitude profile of the area is given in Figure 4a along with two series of ice-depth estimations from surface-impedance data (Fig. 4b). A photograph of the protruding moraines is given in Figure 5.

As with Tl, the instrument was oriented north-south and consequently was almost parallel to the relatively narrow moraine bands. The surface expression of these moraines was approximately 20–30 m wide in all three cases. While there is a dramatic effect at the ice/moraine boundary at the surface, the Tl result suggests that sub-surface mapping of the moraine is not possible using surface-impedance measurements. It is concluded that this plot gives information predominantly about the depth to bedrock under the ice. Rock sizes in the moraines varied up to a maximum of approximately 1 m in height. The complete traverse was pegged at each measurement station and so repeat readings were made in almost exactly the same locations.

The general trend in both traverses is an increase in ice depth to the east. Two of the narrow moraines are clearly evident on Figure 4b as anomalously high ice-depth estimates. It is of interest to note that the slope of the ice immediately in front of the moraines coincides with a rapid increase in elevation of the ice surface. Similarly, the relatively constant ice depth to the east of the moraines coincides with an almost horizontal ice “pool”. All visible rock features, including the exposed rock on the shore and adjacent islands, indicate a very flat rock topography. This is assumed to be the case under the ice cap as well. The parameters used in this model are identical to those used for the T1 analysis with a similar uncertainty estimate.

The very large ice-depth estimate at 100 m coincided with a large pool of water in the ice. Other rapid variations in the first 200 m are thought to result from ice/rock contacts near the surface. These effects are even more dramatic in T3.

Fig.4. Traverse T2 earth-plane cross-section (showing approximate altitude changes) (a), and ice depth deduced from surface-impedance measurements (b).

Fig.5. Photograph of the Leken moraines crossed by T2. The view is to the south with the ocean on the right. The surface expression of the moraines is approximately 1—2 m high.

The only independent depth measurement (Division of National Mapping, 1970) suggests a depth of 160 m at the end of the traverse which lies well within the uncertainty range.

It is assumed that the change in melt conditions on the weathered ice surface to the east of the moraines is the reason for the somewhat different ice-depth determinations between the two traverses.

T3: Penguin Pass

A short traverse was made across an ice-filled basin in the vicinity of Penguin Pass. In this case, the ice was thought to be relatively shallow and was visibly weathered with air and water dispersed in the shallow sub-surface. The two traverses are shown in Figure 6. It is clear in this traverse that the surface impedance over ice is lower than that of the surrounding rock as the traverse started and ended on rock. The general features of the plot include a broad minimum and two maxima close to the edge of the ice bowl. The spot surface-impedance values on the rocks differ from one side to the other. Without the phase information, this profile is impossible to model. It is clear, however, that the surface impedance at the likely maximum ice depth is a minimum. This is contrary to the previous data modelled using two layers only. One can only conclude that either the ice itself is more conductive due to the presence of water or that the bottom of the basin is filled with water-saturated moraine or gravel. The surface-impedance maxima on both sides of the traverse are thought to result from the “rock/air/ice gap caused by the more rapidly changing thermal conditions of the ice close to rock. These peaks are similar to the effect noted at the moraines in traverse T2.

Fig.6. Surface-impedance measurements crossing weathered ice between two rock outcrops (T3 traverse).

T4: Crevasse

A 120 m traverse was made across a crevasse oriented almost parallel to the transmitter bearing angle. This is virtually identical to the situation reported previously (Reference ThielThiel, 1986) where the crevasse lies approximately 20° to the traverse path. The crevasse was almost vertical in orientation and was covered by a 2 m thick snow bridge. Its width at the surface was 3 m, it was at least 30 m deep, and was roughly 400 m long. It appeared to be at least 500 m from other crevasses in the area and so ideal for an investigation into the effect of crevasses on surface-impedance measurements.

Fig.7. T4 surface-impedance measurements across a crevasse in blue ice.

The surface-impedance profile over the slot is shown in Figure 7. Clearly evident at 70 m is a surface-impedance minimum which coincides with the instrument located on the snow bridge covering the crevasse. This indicates that abrupt variations do occur in the vicinity of crevassing. It is worthy of note that, at the 0 m position, the surface impedance is somewhat lower than at the adjacent points, suggesting the presence of another crevasse. None was evident on the surface but an ice cleavage that did not reach the surface may explain the effect. It was unusual that this crevasse was quite isolated.

Comments and ConclusionS

It has been demonstrated that for blue-ice areas a measure of the VLF surface impedance allows ice depths to be determined. While the nature of the surface (i.e. the presence of melt water) does influence the readings and so the resultant ice-depth interpretation, it is thought that this effect can be removed by insulating the instrument chassis from the ice surface, a minor instrument modification. The presence of moraines and crevasses does influence the profiles obtained by showing quite large rapid surface-impedance changes. The computer modelling of traverses Tl and T2 yielded consistent electrical properties of ice and rock which could be used as a guide for future surface-impedance mapping. These numerical values are in keeping with previous ice-depth measurements (Reference ThielThiel, 1986) and Antarctic ice measurements (Reference Glen and ParenGlen and Paren, 1975).

While the complex dielectric properties of ice vary with temperature, frequency, and formation parameters (Reference ReynoldsReynolds, 1985), at the frequency of measurement the depth uncertainties resulting from these unknowns is estimated to result in an error of approximately 10% in the absolute depth. In regions where the ice depth exceeds 800 m, the ice temperature will be important in ice-depth estimations from surface-impedance measurements.

There is good evidence to support the idea that, whereas ice-radar measurements will give information about the first ice/rock interface, surface-impedance measurements have the potential to map beneath narrow moraines and to yield information about gravel layers at bedrock.

Acknowledgements

The authors gratefully acknowledge the assistance of Australian National Antarctic Research Expeditions (ANARE) within the Antarctic Division of the Department of Science in making this research possible, the Glaciology Section of the Department of Meteorology at the University of Melbourne for making available the ice-radar data, and also two grants from Griffith University Research Committee for equipment and salary expenses associated with the project. The authors also wish to thank an anonymous reviewer for drawing attention to the temperature dépendance of electrical characteristics of ice.

References

Betts, M.S. 1981 Australian publications in Antarctic atmospheric sciences, 1974–80. Canberra, Department of Science and Technology. Antarctic Division. (Information Folder 19.)Google Scholar
Division of National Mapping. 1970 Australian Antarctic Territory map No. SQ 49–50. Canberra, Department of National Development.Google Scholar
Glen, J.W. Paren, J.G.. 1975 The electrical properties of snow and ice. J. Glacial., 15(73), 1538.Google Scholar
Reynolds, J.M. 1985 Dielectric behaviour of firn and ice from the Antarctic Peninsula, Antarctica. J. Glacial., 31(109), 253262.Google Scholar
Thiel, D.V. 1986 A preliminary assessment of glacial ice profiling using VLF surface–impedance measurements. J. Glaciol., 32(112), 376382.Google Scholar
Westerlund, S. Reder, F.H.. 1973 VLF radio signals propagating over the Greenland ice–sheet. J. Almos. Terr. Phys., 35(8), 14751491.Google Scholar
Figure 0

Fig.1. Theoretical plot of surface impedance as a function of ice depth above a rock sub-surface with a conductivity of 1.5 × 10−3 S m−1 and dielectric constant of 15Ɛ0. Three different sets of ice parameters have been used: continuous line, conductivity 3 × 10−6 15Ɛ0 dotted line, conductivity 6.6 × 10−6Sm−1. 15Ɛ0; broken line, conductivity 15Ɛ0.

Figure 1

Fig.2. Map of Casey base environs showing the surface-impedance traverse locations T1—T2.

Figure 2

Fig.3. T1 ice-depth profile comparison between ice radar (dots) and surface impedance (crosses).

Figure 3

Fig.4. Traverse T2 earth-plane cross-section (showing approximate altitude changes) (a), and ice depth deduced from surface-impedance measurements (b).

Figure 4

Fig.5. Photograph of the Leken moraines crossed by T2. The view is to the south with the ocean on the right. The surface expression of the moraines is approximately 1—2 m high.

Figure 5

Fig.6. Surface-impedance measurements crossing weathered ice between two rock outcrops (T3 traverse).

Figure 6

Fig.7. T4 surface-impedance measurements across a crevasse in blue ice.