A number of previous studies have suggested that dislocations in ice are electrically charged (Reference Brill and CampBrill and Camp, 1957; Reference ItagakiItagaki, 1970, Reference Itagaki1978; Reference Mae and HigashiMae and Higashi, 1973; Reference Noll, Whalley, Whalley, Jones and Gold.Noll, 1973). Unfortunately, there has been no definite experimental determination of this charge. The previous studies were indirect measurements of the dislocation charge, and the resulting values estimated for the charge density range over several orders of magnitude. Reference Brill and CampBrill and Camp (1957), Reference Noll, Whalley, Whalley, Jones and Gold.Noll (1973), and Reference Mae and HigashiMae and Higashi (1973) reported small but observable changes in the low-frequency (space-charge) region of the dielectric constant for plastically-deformed samples. They associated this phenomenon with a dislocation charge on the order of one unit or less of charge per 106 atomic lengths of dislocation. On the other hand, Itagaki (unpublished) reported large changes in the dielectric constants of samples with deformation. He interprets his X-ray topographic observations (Reference ItagakiItagaki, 1970) of dislocations in samples acted upon by an applied a.c. electric field (60 Hz) in terms of a charge density of one unit of charge per 10-102 atomic dislocation lengths.
The purpose of the present note is to report a direct determination of an upper limit for the charge density of edge dislocations in ice. The determination is based on the observation of the motion of a low-angle tilt boundary, made up of an array of parallel, edge dislocations, under the influence of both an applied mechanical stress σ and an electric field E. For every dislocation segment in the boundary the mechanical force per unit length is bσ, where b is the Burgers' vector, and the electrical force per unit length is λE, where λ is the charge per unit length. For the particular values of σ and E for which the observed displacements (or velocity) of the boundary are equal, the magnitude of the charge per unit length is given entirely in terms of those values
This determination is independent of the nature of the dislocation geometry and of any assumptions about the distribution of the charge along the dislocation.
The single-crystal specimens used in the study were grown by a zone-refining process. The apparatus is similar to that described by Reference RamseierRamseier (unpublished), and is described elsewhere (Reference JoncichJoncich, unpublished, p. 52−53). Individual samples measuring 2 × 1 × 1 cm3 were cut from the 7 cm diameter ingot with a hot-wire saw, and were oriented (to within about 2°) using crossed polarizers. The c-axis lay parallel to one of the 1 cm directions.
A low-angle tilt boundary of approximately 3° was introduced into the specimen by applying a 2 kg mass near to the center of the specimen, in a three-point bending jig, for about 24 h. The specimen temperature during all the tests was approximately —15°C.
The sample was then mounted as shown in Figure 1. The two metal plates were frozen to the two 1 × 1 cm2 faces of the sample. A mechanical stress was applied by applying a mass M on the right-hand metal plate, and a electrical field was applied between the two electrodes. The left-hand brass plate was rigidly fixed, while the right-hand copper plate was free to move. The displacement of the wall could be monitored optically for rough measurements (>0.01 mm), or alternatively the vertical displacement of the right-hand electrode could be measured. For a given displacement d of the wall, the vertical displacement of the right-hand plate is xd tan where is the tilt-angle boundary. The vertical displacements were measured with a Statham displacement gauge (model UC3) used with a PAR model JB-5 lock-in amplifier. The output of the amplifier was displayed on a strip-chart recorder, and the system was calibrated over a range of 0.2 mm using a micrometer screw gauge. The sample and jig were placed within a chamber inside which the temperature was maintained at — 15°C to within 1 deg during the measurements.
For the measurements the tilt boundary was first moved with a mechanical stress. Then, with the mechanical stress still applied, an electric potential difference of 3 250 V was applied between the two metal plates.
This electric field could not be maintained indefinitely, but decayed with a time constant of about five minutes. This decay results from the build-up of space charge at the non-ohmic contacts with the electrodes; this value of the lime constant is in agreement with previous measurements (Reference Engelhardt, Engelhardt, Bullemer, Riehl., Riehl, Riehl, Bullemer and Engelhardt.Engelhardt and others, 1960). Hence, for the present measurements, the electric potential was switched between 0 and ±3 250 V with a period of about 30 s. The resulting electric field in the sample was then either 0 or at least 1 500 V/cm.
The results for one of the several measurements arc shown in Figure 2. The stress of 0.2 bar was applied at time t = 0. After an initial transient period of about 30 s the wall velocity is constant, at 0.24 mm/h, in agreement with the observations of Reference HigashiHigashi and Sakai (1961).
The electric potential was switched between 0 and ±3 250 V at the times indicated. In no case was there any observable change in velocity, so only an upper limit for the charge density can be estimated from the results. As noted, the field inside the sample should be at least 1 500 V/cm during the brief cycles (local field corrections would increase this quantity), and a conservative estimate for the resolution of the velocity is ±2%. From Equation (1), the charge density of the edge dislocations must be less than
This corresponds to only about one unit of charge for every 300 atomic lengths of dislocation. The dislocations in the tilt boundary are of the same sign so that this charge density limit should apply directly to the edge dislocations in the boundary.
The edge dislocation charge density is much less than the upper limit proposed by Reference ItagakiItagaki (1970), but is consistent with the values estimated by Reference HigashiHigashi and Sakai (1961) for screw dislocations. In fact, the edge dislocations could be expected to bave the greatest charge density because they have the largest number of dangling bonds per unit length (Reference Osipiyan and SmirnovaOsipiyan and Smirnova, 1968).
In summary, the present results indicate that dislocations in ice are not heavily charged electrically, so that any charge present is probably associated with a small number of ionic defects distributed along the dislocation (Reference Mae and HigashiMae and Higashi, 1973) rather than a large intrinsic charge associated with each dangling bond at the dislocation core. Further, the results suggest that the large dielectric relaxation peak in ice (Reference SchillerSchiller, 1958) is not the result of charged dislocation motion.
Acknowledgement
The authors are indebted to Dr K. Itagaki of the U.S. Army Cold Regions Research and Engineering Laboratory for his advice concerning the apparatus for the growth and preparation of the ice samples.