Hostname: page-component-78c5997874-8bhkd Total loading time: 0 Render date: 2024-11-17T18:16:11.621Z Has data issue: false hasContentIssue false

The axisymmetric deformation of a red blood cell in uniaxial straining Stokes flow

Published online by Cambridge University Press:  26 April 2006

C. Pozrikidis
Affiliation:
Department of Applied Mechanics and Engineering Sciences, R-011, University of California, San Diego, California 92093, USA

Abstract

The axisymmetric deformation of a red blood cell placed in a uniaxial straining Stokes flow is considered. The cell is modelled as a fluid capsule that contains a Newtonian fluid, and is bounded by an area-preserving membrane with negligible resistance to bending. First, it is theoretically demonstrated that spheroidal cells with isotropic membrane tension constitute stationary configurations. To compute transient cell deformations, a numerical procedure is developed based on the boundary-integral method for Stokes flow. Calculations show that initially prolate or oblate cells with isotropic membrane tension deform into stationary spheroids. Cells with a highly oblate initial shape may develop a persistent small pocket along their axis during the deformation. The shear elasticity of the membrane prevents folding, but may cause the formation of sharp corners and concave regions along the cell contour. A decrease in the membrane shear elasticity results in substantial increase in the magnitude of the transient and asymptotic membrane tensions. The maximum strain rate below which a red blood cell remains intact is estimated to be ex = 105 s−1.

Type
Research Article
Copyright
© 1990 Cambridge University Press

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Barthes-Biesel, D. 1980 Motion of a spherical microcapsule freely suspended in a linear shear flow. J. Fluid Mech. 100, 831853.Google Scholar
Barthes-Biesel, D. & Rallison, J. M. 1981 The time-dependent deformation of a capsule freely suspended in a linear shear flow. J. Fluid Mech. 113, 251267.Google Scholar
Brunn, P. O. 1983 The deformation of a viscous particle surrounded by an elastic shell in a general time-dependent linear flow field. J. Fluid Mech. 126, 533544.Google Scholar
Cerf, R. 1951 Recherches theoriques et experimentales sur l'effet Maxwell des solutions de macromolécules déformables I. Théorie de l'effet Maxwell des suspensions de sphères élastiques. J. Chim. Phys. 48, 5984.Google Scholar
Evans, E. A. & Fung, Y. C. 1972 Improved measurements of the erythrocyte geometry. Microvasc. Res. 4, 335.Google Scholar
Evans, E. A., Waugh, R. & Melnik, L. 1976 Elastic area compressibility modulus of red cell membrane. Biophys. J. 16, 585595.Google Scholar
Evans, E. A. & Skalak, R. 1980 Mechanics and Thermodynamics of Biomembranes. CRC Press.
Fischer, T. M. 1989 Mechanical hemolysis of cross-bonded red cells in the microcirculation. Intl J. Microcirculation: Clin. Exp. 8, 159176.Google Scholar
Fung, Y. C. 1981 Biomechanics. Springer.
Goddard, J. D. & Miller, C. 1967 Nonlinear effects in the rheology of dilute suspensions. J. Fluid Mech. 28, 657673.Google Scholar
Jeffery, G. B. 1922 The motion of ellipsoidal particles immersed in a viscous fluid.. Proc. R. Soc. Lond. A 102, 161179.Google Scholar
Keller, S. R. & Skalak, R. 1982 Motion of a tank-treading ellipsoidal particle in a shear flow. J. Fluid Mech. 120, 2747.Google Scholar
Li, Z. Z., Barthes-Biesel, D. & Helmy, A. 1988 Large deformations and burst of a capsule freely suspended in an elongational flow. J. Fluid Mech. 187, 179196.Google Scholar
Longuet-Higgins, M. S. & Cokelet, E. D. 1976 The deformation of steep surface waves on water I. A numerical method of computation.. Proc. R. Soc. Lond. A 350, 126.Google Scholar
Niimi, H. & Sugihara, M. 1985 Cyclic loading on the red cell membrane in a shear flow: A possible cause of hemolysis. J. Biomech. Engng 107, 9195.Google Scholar
Pozrikidis, C. 1990 The instability of moving viscous drops. J. Fluid Mech. 210, 121.Google Scholar
Rallison, J. M. & Acrivos, A. 1978 A numerical study of the deformation and burst of a viscous drop in an extensional flow. J. Fluid Mech. 89, 191200.Google Scholar
Roscoe, R. 1967 On the rheology of a suspension of viscoelastic spheres in a viscous liquid. J. Fluid Mech. 28, 273293.Google Scholar
Secomb, T. W., Skalak, R., Ozkaya, N. & Gross, J. F. 1986 Flow of axisymmetric red blood cells in narrow capillaries. J. Fluid Mech. 163, 405423.Google Scholar
Skalak, R., Oskaya, N. & Skalak, T. C. 1989 Biofluid mechanics. Ann. Rev. Fluid Mech. 21, 167204.Google Scholar
Tran-Son-Tay, R., Sutera, S. P. & Rao, P. R. 1984 Determination of red blood cell membrane viscosity from rheoscopic observations of tank-treading motion. J. Biophys. Soc. 46, 6572.Google Scholar
Zahalak, G. I., Rao, P. R. & Sutera, S. 1987 Large deformations of a cylindrical liquid-filled membrane by a viscous shear flow. J. Fluid Mech. 179, 283305.Google Scholar