Hostname: page-component-586b7cd67f-dlnhk Total loading time: 0 Render date: 2024-11-22T13:48:35.464Z Has data issue: false hasContentIssue false

Microbiological characterisation and impact of suspended solids on pathogen removal from wastewaters in dairy processing factories

Published online by Cambridge University Press:  29 August 2018

Kelly Fitzhenry
Affiliation:
College of Engineering and Informatics, National University of Ireland, Galway, Ireland
Neil Rowan
Affiliation:
Bioscience Research Institute, Athlone Institute of Technology Athlone, Ireland
William Finnegan
Affiliation:
College of Engineering and Informatics, National University of Ireland, Galway, Ireland Ryan Institute for Environment, Marine and Energy Research, National University of Ireland, Galway, Ireland
Xinmin Zhan
Affiliation:
College of Engineering and Informatics, National University of Ireland, Galway, Ireland Ryan Institute for Environment, Marine and Energy Research, National University of Ireland, Galway, Ireland
Eoghan Clifford*
Affiliation:
College of Engineering and Informatics, National University of Ireland, Galway, Ireland Ryan Institute for Environment, Marine and Energy Research, National University of Ireland, Galway, Ireland
*
*For correspondence; e-mail: [email protected]

Abstract

In this Research Communication we investigate the microbiological profile of 12 dairy wastewater streams from three contrasting Irish dairy processing factories to determine whether faecal indicators/pathogens were present and in turn, whether disinfection may be required for potential water reuse within the factory. Subsequently, the impact of suspended solids on the inactivation efficiency of Escherichia coli via two means of ultravoilet (UV) disinfection; flow-through pulsed UV (PUV) and continuous low pressure UV (LPUV) disinfection was analysed. Faecal indicators total coliforms and E. coli were detected in 10 out of the 12 samples collected at the dairy processing factories while pathogenic bacteria Listeria monocytogenes was detected in all samples collected at 2 out of the 3 factories. Salmonella spp. was undetected in all samples. The results also indicated that organic dairy wastewater solids had an impact on the performance efficiency of the PUV system and, to a lesser extent, the LPUV system. The findings indicate that the targeting of key pathogens would be required to enable wastewater reuse (and indeed effluent discharges if regulation continues to become more stringent) and that LPUV may offer a more robust disinfection method as it appears to be less susceptible to the presence of suspended solids.

Type
Research Article
Copyright
Copyright © Hannah Dairy Research Foundation 2018 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

ADIC 2013 Australian dairy industry sustainability framework progress report 2013. Australian Dairy Industry Council Inc., Victoria, AustraliaGoogle Scholar
Dairy UK 2015 Dairy roadmap 2015. Dairy UK Ltd., London, EnglandGoogle Scholar
Deloitte 2015 Optimising water reuse in the EU – Final report prepared for the European Commission (DG ENV), Part I. Deloitte Ltd in collaboration with ICF and Cranfield University, London, EnglandGoogle Scholar
Fitzhenry, K, Barrett, M, O'Flaherty, V, Dore, W, Keaveney, S, Cormican, M & Clifford, E 2014 Detection and removal of pathogenic norovirus employing tertiary treatment in wastewater and water treatment facilities. Water Practice & Technology 9 370376Google Scholar
Geraghty, R 2011 Resource efficiency in Ireland's dairy processing sector. Enterprise Ireland, Dublin, IrelandGoogle Scholar
Gopal, N, Hill, C, Ross, PR, Beresford, TP, Fenelon, MA & Cotter, PD 2015 The prevalence and control of Bacillus and related spore-forming bacteria in the dairy industry. Frontiers in Microbiology 6 118Google Scholar
Oliver, SP, Jayarao, BM & Almeida, RA 2005 Foodborne pathogens in milk and the dairy farm environment: food safety and public health implications. Foodborne Pathogens and Disease 2 115129Google Scholar
Riera, FA, Suárez, A & Muro, C 2013 Nanofiltration of UHT flash cooler condensates from a dairy factory: characterisation and water reuse potential. Desalination 309 5263Google Scholar
UKWIR 2016 Effect of turbidity on the efficiency of disinfection of waterborne bacteria. UK Water Industry Research Ltd., London, EnglandGoogle Scholar
Supplementary material: PDF

Fitzhenry et al. supplementary material

Figures S1-S4

Download Fitzhenry et al. supplementary material(PDF)