Hostname: page-component-586b7cd67f-dlnhk Total loading time: 0 Render date: 2024-11-23T11:30:24.580Z Has data issue: false hasContentIssue false

4209 Early Electrographic Seizure Detection by Neuro ICU Nurses via Bedside Real-Time Quantitative EEG

Published online by Cambridge University Press:  29 July 2020

Safa Kaleem
Affiliation:
Duke University
Jennifer H. Kang
Affiliation:
Duke University
Alok Sahgal
Affiliation:
Duke University
Christian E. Hernandez
Affiliation:
Duke University
Christa B. Swisher
Affiliation:
Duke University
Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

OBJECTIVES/GOALS:

  1. 1. Determine test characteristics of Neuro ICU nurse interpretation of real-time bedside qEEG for seizure detection

  2. 2. Determine difference in time to detection of seizures between qEEG interpretation and raw cEEG reads

  3. 3. Determine how seizure characteristics affect accuracy of qEEG reads

METHODS/STUDY POPULATION:

  • Subjects: Nurses caring for patients admitted to the Neuro ICU at Duke University Hospital who are initiated on cEEG.

  • Nurses evaluate qEEG display at the bedside on an hourly basis after undergoing a standardized qEEG training session. The standard practice of independent review of cEEG and treatment by the Neuro ICU team remains unchanged.

  • Post-hoc review of cEEG data by two blinded, board-certified neurophysiologists will be performed for each patient. The raw cEEG data will be scored for the number of seizures present per hour, background, seizure duration, and seizure spatial extent.

  • The time from first seizure occurrence to clinical recognition will be recorded.

RESULTS/ANTICIPATED RESULTS:

  • Thus far, 91 patients with 583 1-hour blocks of nurse interpretations have been studied, with 6 patients experiencing seizures while on study. Enrollment will be completed on 1/17/20

  • Preliminary data show a sensitivity of 95.8% (79.9%, 99.9%), specificity of 95.2 (93.1%, 96.8%), positive predictive value of 46.0% (36.9%, 55.4%), negative predictive value of 99.8% (98.7%, 99.9%), positive likelihood ratio of 19.8 (13.6, 28.9), negative likelihood ratio (0.04 (0.01, 0.3). All confidence intervals are 95%. False alarm rate is 0.05/hour.

  • Further analyses are pending completion of enrollment in January 2020.

DISCUSSION/SIGNIFICANCE OF IMPACT: Nurse interpretation of real-time bedside qEEG for seizure detection is feasible in the Duke Neuro ICU. QEEG functions well as a screening tool with good specificity and low false alarm rate. Use of qEEG by nurses could lead to shorter time to seizure detection, which may improve patient outcomes. CONFLICT OF INTEREST DESCRIPTION: Safa Kaleem, BS: Research reported in this publication was supported by a Pfizer Foundation grant and the Duke Clinical Translational Science Institute (CTSI). The content is solely the responsibility of the authors and does not necessarily represent the official views of the Pfizer Foundation or the Duke CTSI. Jennifer H. Kang, MD: None to declare. Alok Sahgal, MD: None to declare. Christa B. Swisher, MD: Received speaker’s honorarium from EISAI and UCB.

Type
Clinical Epidemiology/Clinical Trial
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright
© The Association for Clinical and Translational Science 2020

Footnotes

Gold Ribbon Awardee