Hostname: page-component-745bb68f8f-l4dxg Total loading time: 0 Render date: 2025-01-15T19:39:32.882Z Has data issue: false hasContentIssue false

PP104 Utility Of Chemiluminescence Detection Of Anti-Domain 1 β2 Glycoprotein I Antibodies In Antiphospholipid Syndrome

Published online by Cambridge University Press:  07 January 2025

Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.
Introduction

Patients with antiphospholipid syndrome (APS) present a significant risk of thrombotic events or morbidity during pregnancy, associated with the presence of persistently positive antiphospholipid antibodies (aPL). The risk stratification is crucial to adopt primary prophylaxis measures. With this objective, assays for the in vitro detection of anti-domain 1 β2 glycoprotein I (aD1 IgG) antibodies by chemiluminescence immunoassay (CLIA) have been developed.

Methods

We conducted a systematic review with meta-analyses on the effectiveness of incorporating aD1 IgG detection by CLIA for the identification of patients with APS at high risk of thrombosis or morbidity during pregnancy. A cost analysis was also conducted using a decision tree model from the perspective of the Spanish National Health System and a time horizon of three months. We ran extensive sensitivity analyses. Twelve diagnostic performance studies with a total of 3,570 patients were selected.

Results

The sensitivity and specificity of aD1 IgG added to the conventional aPL criteria for obstetric and thrombotic manifestations ranged from 15 to 16 percent, and from 94 to 97 percent, respectively. The sensitivity of the detection of aD1 IgG in isolation for thrombotic and obstetric manifestations was 29 and 48 percent, and specificity was 60 percent, respectively. The GRADE quality of evidence was very low due to the risk of bias and indirectness issues. The incorporation of the aD1 IgG detection involves a higher cost per patient than the usual clinical practice, with an incremental difference of EUR24.04 (USD26.01).

Conclusions

Despite its potential, the incorporation of the aD1 IgG detection by CLIA as an additional test to the determination of classical aPL for the identification of patients with APS at high thrombotic or obstetric risk may not be feasible due to the very low available evidence on diagnostic performance and increased costs.