Hostname: page-component-cd9895bd7-jn8rn Total loading time: 0 Render date: 2024-12-26T13:40:58.687Z Has data issue: false hasContentIssue false

Design of ramp-time current control with dynamic fuzzy bandwidth for wireless power transmission

Published online by Cambridge University Press:  14 August 2015

Leong Wen Chek*
Affiliation:
Power Electronics and Renewable Energy Research Lab (PEARL), Department of Electrical Engineering, University of Malaya, 50603 Kuala Lumpur, Malaysia. Phone: +60126170333 Research and Development Department, Motorola Solutions (M) Sdn Bhd, 11900 Bayan Lepas, Malaysia
Saad Mekhilef
Affiliation:
Power Electronics and Renewable Energy Research Lab (PEARL), Department of Electrical Engineering, University of Malaya, 50603 Kuala Lumpur, Malaysia. Phone: +60126170333
Erwan Sulaiman
Affiliation:
Faculty of Electrical and Electronics, Universiti Tun Hussein Onn, 86400 Batu Pahat, Malaysia
Macwien Krishnamurthi
Affiliation:
Research and Development Department, Motorola Solutions (M) Sdn Bhd, 11900 Bayan Lepas, Malaysia
*
Corresponding author: L. Wen Chek Email: [email protected]

Abstract

This paper presents a novel experimental simulation of ramp-time current control with fuzzy bandwidth for wireless power transmission (WPT) systems. A fuzzy logic control algorithm was designed based on the structure of ramp-time current control in active power filters through simulation of ramp-time bandwidth variation to dynamically adjust the loop width of the ramp-time comparator. Ramp-time current control is the most suitable over other current control techniques and is thus selected for the experiment. Implementation of this approach prevents over-limit of switching frequency and enhances dynamic responses, resulting in long lifespan of power switches and smooth output for WPT systems. Finally, the hypothesis and simulation results were verified by analyzing the prototype model and experiment results.

Type
Research Papers
Copyright
Copyright © Cambridge University Press and the European Microwave Association 2015 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

[1] El-Habrouk, M.; Darwish, M.; Mehta, P.: Active power filters: a review. IEEE Proc. Electric Power Appl., 147 (2000), 403413.CrossRefGoogle Scholar
[2] Akagi, H.; Nabae, A.; Atoh, S.: Control strategy of active power filters using multiple voltage-source PWM converters. IEEE Trans. Ind. Appl., IA-22 (3) (1986), 460465.CrossRefGoogle Scholar
[3] Lascu, C.; Asiminoaei, L.; Boldea, I.; Blaabjerg, F.: High performance current controller for selective harmonic compensation in active power filters. IEEE Transact. Power Electron., 22 (2007), 18261835.CrossRefGoogle Scholar
[4] Peng, F.Z.: Application issues of active power filters. IEEE Ind. Appl. Mag,, 4 (1998), 2130.Google Scholar
[5] Akagi, H.: New trends in active filters for power conditioning. IEEE Transact. Ind. Appl., 32 (1996), 13121322.Google Scholar
[6] Akagi, H.: New trends in active filters for improving power quality, in Power Electronics, Drives and Energy Systems for Industrial Growth, 1996, in Proceedings of the 1996 Int. Conf., 1996, 417–425.Google Scholar
[7] Rahman, S.; Ratrout, N.T.: Review of the fuzzy logic based approach in traffic signal control: prospects in Saudi Arabia. J. Transp. Syst. Eng. Inf. Technol., 9 (2009), 5870.Google Scholar
[8] Borle, L.J.; Nayar, C.V.: Ramptime current control [for power convertors], in Applied Power Electronics Conf. and Exposition, 1996. APEC'96. Conf. Proceedings 1996, Eleventh Annual, 1996, 828–834.Google Scholar
[9] Daniyal, H.; Borle, L.J.; Lam, E.; Iu, H.: Design and development of digital ramptime current control technique, in IEEE 8th Int. Conf. on Power Electronics and ECCE Asia (ICPE & ECCE), 2011, 2011, 2092–2099.Google Scholar
[10] Han, Y. et al. : The adaptive signal processing scheme for power quality conditioning applications based on active noise control (ANC), Elektron. Elektrotech., 96 (8) (2015), 914.Google Scholar
[11] Han, Y. et al. : Power quality enhancement for automobile factory electrical distribution system-strategies and field practice. PrzeglądElektrotechniczny, 85 (2009), 159163.Google Scholar
[12] Saeedifard, M.; Bakhshai, A.; Joos, G.: Low switching frequency space vector modulators for high power multimodule converters. IEEE Transact. Power Electron., 20 (2005), 13101318.Google Scholar
[13] Sanbo, P.; Zong-xinag, C.; Jun-min, P.: A novel SVPWM method for DC rail resonant inverter. Proc. CSEE, 27 (2007), 6569.Google Scholar
[14] Kumar, M.N.; Vasudevan, K.: Bi-directional real and reactive power control using constant frequency hysteresis control with reduced losses. Electric Power Syst. Res., 76 (2005), 127135.Google Scholar
[15] Poulsen, S.; Andersen, M.A.: Hysteresis controller with constant switching frequency. IEEE Transact. Consumer Electron., 51 (2005), 688693.Google Scholar
[16] Nakajima, N.; Kuramoto, M.; Kinoshita, K.; Utano, T.: A system design for TDMA mobile radios, in 1990 IEEE 40th Vehicular Technology Conf., 1990, 295–298.Google Scholar
[17] Qasim, M.; Kanjiya, P.; Khadkikar, V.: Artificial-neural-network-based phase-locking scheme for active power filters, IEEE Transact. Ind. Electron., 61 (8) (2014), 3857–3866.Google Scholar
[18] Borle, L.: Four quadrant power flow in a ramptime current controlled converter, in Conf. Proceedings 1996, Applied Power Electronics Conf. and Exposition, 1996, APEC'96, Eleventh Annual, 1996, 898–904.Google Scholar
[19] Cirrincione, M.; Pucci, M.; Vitale, G.; Miraoui, A.: Current harmonic compensation by a single-phase shunt active power filter controlled by adaptive neural filtering. IEEE Transact. Ind. Electron., 56 (2009), 31283143.CrossRefGoogle Scholar
[20] Parrillo, L.C.: Wireless motor vehicle diagnostic and software upgrade system. ed: Google Patents, 1995.Google Scholar
[21] Diaz, M.; Sligo, J.: How software process improvement helped Motorola. IEEE software, 14 (1997), 7581.Google Scholar
[22] Lisauskas, S.; Rinkevičienė, R.: Model of Ventilation System Drive with Fuzzy Controller, Electronics and Electrical Engineering, Technologija, Kaunas, 2010, 106.Google Scholar
[23] Gupta, T.; Boudreaux, R.; Nelms, R.; Hung, J.Y.: Implementation of a fuzzy controller for DC-DC converters using an inexpensive 8-b microcontroller. IEEE Transact. Ind. Electron., 44 (1997), 661669.Google Scholar
[24] Kurs, A.; Karalis, A.; Moffatt, R.; Joannopoulos, J.D.; Fisher, P.; Soljačić, M.: Wireless power transfer via strongly coupled magnetic resonances. Science, 317 (2007), 8386.CrossRefGoogle ScholarPubMed
[25] Brown, M.; Harris, C.J.: Neurofuzzy Adaptive Modelling and Control. Prentice Hall, New York, 1994.Google Scholar
[26] Pedrycz, W.; Gomide, F.: An Introduction to Fuzzy Sets: Analysis and Design. MIT Press, Cambridge, MA, 1998.Google Scholar
[27] Institute of Electrical and Electronics Engineer: IEEE Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems, available at: http://intecol.com.co/wordpress/wp-content/uploads/2013/01/IEEE519-1992.pdf (1993).Google Scholar
[28] Buso, S.; Malesani, L.; Mattavelli, P.: Comparison of current control techniques for active filter applications. IEEE Transact. Ind. Electron., 45 (1998), 722729.Google Scholar