Hostname: page-component-586b7cd67f-dlnhk Total loading time: 0 Render date: 2024-11-29T11:32:47.840Z Has data issue: false hasContentIssue false

The IRAM Interferometer on Plateau de Bure

Published online by Cambridge University Press:  12 April 2016

S. Guilloteau*
Affiliation:
Institut de Radioastronomie Millimétrique (IRAM), 300 Rue de la Piscine, 38406 Saint Martin d’Hères, France

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

In November 1992, the IRAM interferometer on Plateau de Bure has reach two years of operation. After a review of its current technical status, with emphasis on its specificities, this paper presents an overview of its capabilities, illustrated by examples taken from the scientific program carried on during these two years. On-going upgrades and future plans are presented.

Type
1. Recent Developments and Upgrading Plans for the Near Future
Copyright
Copyright © Astronomical Society of the Pacific 1994

References

Bos, A. 1986, The NFRA Correlator Chip (NFRA-ITR-176: Dwingeloo)Google Scholar
Delannoy, J. 1985, in (Sub)Millimeter Astronomy, ed. Shaver, P. A. & Kjär, K. (ESO: Garching) p25 Google Scholar
Delannoy, J. 1991, in Radio Interferometry: Theory, Techniques, and Applications, ed. Cornwell, T. J. & Perley, R. A., (ASP, San Francisco) p15 Google Scholar
Downes, D., Radford, S.J.E., Guilloteau, S., Guélin, M., Greve, A., & Morris, D. 1992, A&A, 262, 624 Google Scholar
Guilloteau, S. 1990, OBS User’s Guide (IRAM: Grenoble)Google Scholar
Guilloteau, S., Delannoy, J., Downes, D., Greve, A., Guélin, M., Lucas, R., Morris, D., Radford, S.J.E., Wink, J., Cernicharo, J., Forveille, T., Garcia-Burillo, S., Neri, R., Blondel, J., Perrigouard, A., Plathner, D., Torres, M., 1992, A&A 262 624 Google Scholar
Guilloteau, S., & Forveille, T., 1989, Grenoble Image and Line Data Analysis System (GILDAS; IRAM: Grenoble)Google Scholar
Guilloteau, S., Dutrey, A., Marten, A., & Gautier, D., 1993, A&A submittedGoogle Scholar
Lucas, R., 1992, Continuum and Line Interferometer Calibration (CLIC; IRAM: Grenoble)Google Scholar
Lucas, R., 1993, this volumeGoogle Scholar
Lucas, R., Bujarrabal, V., Guilloteau, S., Bachiller, R., Baudry, A., Cernicharo, J., Delannoy, J., Forveille, T., Guélin, M., & Radford, S.J.E. 1992, A&A, 262, 491 Google Scholar
Neri, R., Garcia-Burillo, S., Guélin, M., Cernicharo, J., Guilloteau, S., & Lucas, R., 1992, A&A, 262, 544 Google Scholar
Plambeck, R.L., Wright, M.C.H., & Carlstrom, J.E., 1990, ApJ 348, L65 Google Scholar
Rieu, N.Q., Viallefond, F., Combes, F., Jackson, J., Lequeux, J., Radford, S.J.E., Bach., T., 1993, this volumeGoogle Scholar
Simon, M., & Guilloteau, S., 1992, ApJ, 397, L47 Google Scholar