Hostname: page-component-78c5997874-8bhkd Total loading time: 0 Render date: 2024-11-19T05:29:33.797Z Has data issue: false hasContentIssue false

Utility of an Adenosine Triphosphate Bioluminescence Assay to Evaluate Disinfection of Clostridium difficile Isolation Rooms

Published online by Cambridge University Press:  02 January 2015

Abhishek Deshpande
Affiliation:
Department of Medicine, Division of Infectious Diseases, Case Western Reserve University, Cleveland, Ohio
Brett Sitzlar
Affiliation:
Department of Medicine, Division of Infectious Diseases, Case Western Reserve University, Cleveland, Ohio
Dennis Fertelli
Affiliation:
Department of Medicine, Division of Infectious Diseases, Case Western Reserve University, Cleveland, Ohio
Sirisha Kundrapu
Affiliation:
Department of Medicine, Division of Infectious Diseases, Case Western Reserve University, Cleveland, Ohio
Venkata C. K. Sunkesula
Affiliation:
Department of Medicine, Division of Infectious Diseases, Case Western Reserve University, Cleveland, Ohio
Amy J. Ray
Affiliation:
Department of Medicine, Division of Infectious Diseases, Case Western Reserve University, Cleveland, Ohio
Curtis J. Donskey*
Affiliation:
Geriatric Research, Education and Clinical Center, Cleveland Veterans Affairs Medical Center, Cleveland, Ohio
*
Geriatric Research, Education, and Clinical Center, Cleveland Veterans Affairs Medical Center, 10701 East Boulevard, Cleveland, OH 44106 ([email protected])

Extract

Effective disinfection of hospital rooms after discharge of patients with Clostridium difficile infection (CDI) is necessary to prevent transmission. Unfortunately, several studies have demonstrated that it is not uncommon for environmental cultures to remain positive for C. difficile after cleaning and disinfection of rooms in which a patient with CDI has been hospitalized (CDI rooms) by environmental services personnel. Cultures for C. difficile could potentially be useful to monitor disinfection of CDI rooms, but they are neither widely available nor efficient. There is a need for easy-to use and rapid methods to assess the effectiveness of CDI room disinfection. Adenosine triphosphate (ATP) bioluminescence assays provide a rapid assessment of cleaning effectiveness, because detection of ATP on surfaces indicates the presence of residual organic material (eg, bacteria, human secretions or excretions, and food). Detection of ATP is commonly used in the food and beverage industry and is increasingly being used in health care facilities to assess the adequacy of cleaning procedures. It is not known whether measurement of ATP on surfaces is useful to evaluate disinfection of CDI rooms. Here, we tested the hypothesis that low ATP readings on cleaned surfaces in CDI rooms would be predictive of negative cultures for C. difficile.

Type
Research Briefs
Copyright
Copyright © The Society for Healthcare Epidemiology of America 2013

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Eckstein, BC, Adams, DA, Eckstein, EC, et al.Reduction of Clostridium difficile and vancomycin-resistant enterococcus contamination of environmental surfaces after an intervention to improve cleaning methods. BMC Infect Dis 2007;7:61.CrossRefGoogle ScholarPubMed
2.Boyce, JM, Havill, NL, Otter, JA, et al.Impact of hydrogen peroxide vapor room decontamination on Clostridium difficile environmental contamination and transmission in a healthcare Setting. Infect Control Hosp Epidemiol 2008;29(8):723729.CrossRefGoogle Scholar
3.Nerandzic, MM, Donskey, CJ. Effective and reduced-cost modified selective medium for isolation of Clostridium difficile. J Clin Microbiol 2009;47(2):397400.CrossRefGoogle ScholarPubMed
4.Boyce, JM, Havill, NL, Dumigan, DG, Golebiewski, M, Balogun, O, Rizvani, R. Monitoring the effectiveness of hospital cleaning practices by use of an adenosine triphosphate bioluminescence assay. Infect Control Hosp Epidemiol 2009;30(7):678684.Google Scholar
5.Boyce, JM, Havill, NL, Havill, HL, Mangione, E, Dumigan, DG, Moore, BA. Comparison of fluorescent marker systems with 2 quantitative methods of assessing terminal cleaning practices. Infect Control Hosp Epidemiol 2011;32(12):11871193.CrossRefGoogle ScholarPubMed
6.Lewis, T, Griffith, C, Gallo, M, Weinbren, M. A modified ATP benchmark for evaluating the cleaning of some hospital environmental surfaces. J Hosp Infect 2008;69(2):156163.Google Scholar