Hostname: page-component-586b7cd67f-2plfb Total loading time: 0 Render date: 2024-11-27T02:35:46.185Z Has data issue: false hasContentIssue false

Ultraviolet Powder versus Ultraviolet Gel for Assessing Environmental Cleaning

Published online by Cambridge University Press:  02 January 2015

L. Silvia Munoz-Price*
Affiliation:
Division of Infectious Diseases, Department of Medicine, University of Miami, Miami, Florida Department of Epidemiology and Publich Health, University of Miami, Miami, Florida Jackson Memorial Hospital, Miami, Florida
Yovanit Fajardo-Aquino
Affiliation:
Jackson Memorial Hospital, Miami, Florida
Kristopher L. Arheart
Affiliation:
Division of Biostatistics, University of Miami, Miami, Florida Department of Epidemiology and Publich Health, University of Miami, Miami, Florida
*
Park Plaza West L-302, 1611 NW, 12th Avenue, Miami, FL 33136-1096 ([email protected])

Abstract

We compared cleaning rates associated with use of a white ultraviolet (UV) powder versus a transparent UV gel among units with various degrees of previous experience with UV powder. The study outcome was the presence of discordant cleaning (removal of powder without the removal of gel, or vice versa). We found higher frequency of discordance in high-experience units (31%) than in no-experience units (8%) (P<.001). In 92% of discordant findings, the powder was removed but not the gel (P< .001). These findings suggest preferential cleaning of visible UV targets among units with high levels of previous experience with powder.

Infect Control Hosp Epidemiol 2012;33(2):192-195

Type
Concise Communications
Copyright
Copyright © The Society for Healthcare Epidemiology of America 2012

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Hota, B. Contamination, disinfection, and cross-colonization: are hospital surfaces reservoirs for nosocomial infection? Clin Infect Dis 2004;39:11821189.Google Scholar
2.Otter, JA, Yezli, S, French, GL. The role played by contaminated surfaces in the transmission of nosocomial pathogens. Infect Control Hosp Epidemiol 2011;32:687699.Google Scholar
3.Huang, SS, Datta, R, Piatt, R. Risk of acquiring antibiotic-resistant bacteria from prior room occupants. Arch Intern Med 2006;166:19451951.Google Scholar
4.Bhalla, A, Pultz, NJ, Gries, DM, et al. Acquisition of nosocomial pathogens on hands after contact with environmental surfaces near hospitalized patients. Infect Control Hosp Epidemiol 2004;25:164167.Google Scholar
5.Hayden, MK, Bonten, MJ, Blom, DW, Lyle, EA, van de Vijver, DA, Weinstein, RA. Reduction in acquisition of vancomycin-resistant enterococcus after enforcement of routine environmental cleaning measures. Clin Infect Dis 2006;42:15521560.Google Scholar
6.Duckro, AN, Blom, DW, Lyle, EA, Weinstein, RA, Hayden, MK. Transfer of vancomycin-resistant enterococci via health care worker hands. Arch Intern Med 2005;165:302307.Google Scholar
7.Boyce, JM, Potter-Bynoe, G, Chenevert, C, King, T. Environmental contamination due to methicillin-resistant Staphylococcus aureus: possible infection control implications. Infect Control Hosp Epidemiol 1997;18:622627.Google Scholar
8.Munoz-Price, LS, Weinstein, RA. Acinetobacter infection. N Engl J Med 2008;358:12711281.Google Scholar
9.Datta, R, Piatt, R, Yokoe, DS, Huang, SS. Environmental cleaning intervention and risk of acquiring multidrug-resistant organisms from prior room occupants. Arch Intern Med 2011;171:491494.Google Scholar
10.Carling, PC, Parry, MF, Bruno-Murtha, LA, Dick, B. Improving environmental hygiene in 27 intensive care units to decrease multidrug-resistant bacterial transmission. Crit Care Med 2010;38:10541059.Google Scholar
11.Carling, PC, Parry, MM, Rupp, ME, Po, JL, Dick, B, Von Beheren, S; Healthcare Environmental Hygiene Study Group. Improving cleaning of the environment surrounding patients in 36 acute care hospitals. Infect Control Hosp Epidemiol 2008;29:10351041.Google Scholar
12.Jefferson, J, Whelan, R, Dick, B, Carling, P. A novel technique for identifying opportunities to improve environmental hygiene in the operating room. AORN J 2011;93:358364.Google Scholar
13.Munoz-Price, LS, Ariza-Heredia, E, Adams, S, et al. Use of UV Powder for surveillance to improve environmental cleaning. Infect Control Hosp Epidemiol 2011;32:28385.Google Scholar
14.Boyce, JM, Havill, NL, Dumigan, DG, Golebiewski, M, Balogun, O, Rizvani, R. Monitoring the effectiveness of hospital cleaning practices by use of an adenosine triphosphate bioluminescence assay. Infect Control Hosp Epidemiol 2009;30:678684.CrossRefGoogle ScholarPubMed
15.Rutala, WA, Weber, DJ. Are room decontamination units needed to prevent transmission of environmental pathogens? Infect Control Hosp Epidemiol 2011;32:743747.Google Scholar