Subclavian Hemodialysis Catheter Infections: A Prospective, Randomized Trial of an Attachable Silver-impregnated Cuff for Prevention of Catheter-related Infections

Published online by Cambridge University Press:  02 January 2015

Philip J. Dahlberg
Affiliation:
Section of Nephrology, Gundersen Clinic, Ltd, La Crosse, Wisconsin
William A. Agger
Affiliation:
Section of Infectious Diseases, Gundersen Clinic, Ltd, La Crosse, Wisconsin
James R. Singer
Affiliation:
Section of Nephrology, Gundersen Clinic, Ltd, La Crosse, Wisconsin
Wilfrido R. Yutuc
Affiliation:
Section of Nephrology, Gundersen Clinic, Ltd, La Crosse, Wisconsin
Kermit L. Newcomer
Affiliation:
Section of Nephrology, Gundersen Clinic, Ltd, La Crosse, Wisconsin
Ana Schaper
Affiliation:
Gundersen Medical Foundation, Gundersen Clinic, Ltd, La Crosse, Wisconsin
Brenda L. Rooney
Affiliation:
Gundersen Medical Foundation, Gundersen Clinic, Ltd, La Crosse, Wisconsin

Abstract

Objective:

To determine if an attachable silver-impregnated cuff is effective in reducing subclavian hemodialysis catheter-related infections.

Design:

Prospective, randomized, nonblinded study.

Setting:

Community teaching hospital.

Patients:

One hundred one acute and chronic renal failure patients requiring subclavian venipuncture and catheterization. After randomization, 47 patients underwent subclavian catheterization with a silver-impregnated cuff (Ag-CC), and 54 patients had routine catheter (RC) placements.

Measurements:

Multiple presumed predictor variables for catheter-related infections, exit site infection rate, bacteremia rates, and semiquantitative cultures of all catheters.

Results:

There were no significant differences between the AG-CC and the RC groups for catheter colonization, exit site infection, catheter sepsis, any catheter-related infections, or the incidence of infections within the first 7 or 14 days. Although the differences did not achieve statistical significance, the RC group was more likely to experience catheter colonization (20.4% versus 14.9%) and exit site infection (5.6% versus 2.1%). However, the RC group contained nearly twice as many intensive care (ICU) patients (44% versus 23%; P=.027), and ICU subjects were twice as likely to acquire catheter infection (P<.002).

Conclusions:

Although the sample size was insufficient to exclude Type 2 errors, it appears that the attachable silver-impregnated cuff did not reduce subclavian catheter-related infections in our patient population.

Type
Original Articles
Copyright
Copyright © The Society for Healthcare Epidemiology of America 1995

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Siddiqui, JY, Fitz, AE, Lawton, RL, et al. Causes of death in patients receiving long-term hemodialysis. JAMA 1970;212:13501354.CrossRefGoogle ScholarPubMed
2. Burton, BT, Krueger, KK Jr. National registry of long-term dialysis patients. JAMA 1971;218:718722.CrossRefGoogle Scholar
3. Lowrie, EG, Lazarus, JM, Mocelin, AJ, et al. Survival of patients undergoing chronic hemodialysis and renal transplantation. N Engl J Med 1973;288:863867.CrossRefGoogle ScholarPubMed
4. Kirmani, N, Tuazon, CU, Murray, HW, Parrish, AE, Sheagren, JN. Staphylococcus aureus carriage rate of patients receiving long-term hemodialysis. Arch Intern Med 1978;138:16571659.Google Scholar
5. Goldblum, SE, Ulrich, JA, Goldman, RS, Reed, WP. Nasal and cutaneous flora among hemodialysis patients and personnel: quantitative and qualitative characterization and patterns of staphylococcal carriage. Am J Kidney Dis 1982;2:281286.Google Scholar
6. Uldall, PR, Merchant, N, Woods, F, Yarworski, U, Vas, S. Changing subclavian hemodialysis cannulas to reduce infection. Lancet 1981;1:1373.CrossRefGoogle ScholarPubMed
7. Sherertz, RJ, Falk, RJ, Huffman, KA, Thomann, CA, Mattern, WD. Infections associated with subclavian Uldall catheters. Arch Intern Med 1983;143:5256.CrossRefGoogle ScholarPubMed
8. Kozeny, GA, Venezio, FR, Bansal, VK, Vertuno, LL, Hano, JE. Incidence of subclavian dialysis catheter-related infections. Arch Intern Med 1984;144:17871789.CrossRefGoogle ScholarPubMed
9. Cheesbrough, JS, Finch, RG, Burden, RP. A prospective study of the mechanisms of infection associated with hemodialysis catheters. J Infect Dis 1986;154:579588.CrossRefGoogle ScholarPubMed
10. Dahlberg, PJ, Yutuc, WR, Newcomer, KL. Subclavian hemodialysis catheter infections. Am J Kidney Dis 1986;7:421427.Google Scholar
11. Maki, DG, Cobb, L, Garman, JK, et al. An attachable silver-impregnated cuff for prevention of infection with central venous catheters: a prospective randomized multicenter trial. Am J Med 1988;85:307314.Google Scholar
12. Flowers, RH, Schwenzer, KJ, Kopel, RF, et al. Efficacy of an attachable subcutaneous cuff for the prevention of intravascular catheter-related infection. A randomized, controlled trial. JAMA 1989;261:878883.Google Scholar
13. Maki, DG, Weise, CE, Sarafin, HW. A semiquantitative culture method for identifying intravenous catheter-related infections. N Engl J Med 1977;296:13051309.Google Scholar
14. SAS Institute. SAS/STAT User's Guide, Release. 6.03rd ed. Cary, NC: SAS Institute Inc; 1988.Google Scholar
15. Mehta, CR, Patel, NR, Gray, R. Computing an exact confidence interval for the common odds ratio in several 2 x 2 contingency tables. J Am Statistical Assoc 1985;80:969973.Google Scholar
16. Yu, VL, Goetz, A, Wagener, M, et al. Staphylococcus aureus nasal carriage and infection in patients on hemodialysis, efficacy of antibiotic prophylaxis. N Engl J Med 1986;315:9196.CrossRefGoogle ScholarPubMed
17. Almirall, J, Gonzalez, J, Rello, J, et al. Infection of hemodialysis catheters: incidence and mechanisms. Am J Nephrol 1989;9:454459.CrossRefGoogle ScholarPubMed
18. Cimochowski, GE, Worley, E, Rutherford, WE, et al. Superiority of the internal jugular over the subclavian access for temporary dialysis. Nephron 1990;54:154161.CrossRefGoogle ScholarPubMed
19. Canaud, B, Beraud, JJ, Joyenx, H, Mion, C. Internal jugular vein cannulation using 2 Silastic catheters. A new, simple and safe long-term vascular access for extracorporeal treatment. Nephron 1986;43:133136.Google Scholar
20. Kamal, GD, Pfaller, MA, Rempe, LE, et al. Reduced intravascular catheter infection by antibiotic bonding. A prospective, randomized, controlled trial. JAMA 1991;265:23642368.Google Scholar