Hostname: page-component-cd9895bd7-q99xh Total loading time: 0 Render date: 2024-12-23T13:34:53.409Z Has data issue: false hasContentIssue false

Reliability Testing for Portable Adenosine Triphosphate Bioluminometers

Published online by Cambridge University Press:  02 January 2015

Greg S. Whiteley*
Affiliation:
University of Western Sydney, Hawkesbury Campus, Richmond, New South Wales, Australia Whiteley Corporation Pty Ltd, North Sydney, New South Wales, Australia
Chris Derry
Affiliation:
University of Western Sydney, Hawkesbury Campus, Richmond, New South Wales, Australia
Trevor Glasbey
Affiliation:
Whiteley Corporation Pty Ltd, North Sydney, New South Wales, Australia
*
Corporation Pty Ltd, PO Box 1076, North Sydney, New South Wales 2059, Australia ([email protected])

Extract

Measurement of adenosine triphosphate (ATP) using portable bioluminometers has been adapted from the food manufacturing sector, and it has been suggested that it could be used as an indicator of surface soiling or cleanliness in hospital settings. Some healthcare authorities are considering the use of portable ATP bioluminometers as a tool for standard setting for surface cleanliness to improve cleaning standards. Central to this approach is the use of a commonly accepted level of detected ATP—expressed as relative light units (RLUs)—that may be used as a surrogate for underlying soiling, including the presence of pathogenic microorganisms.

It has been demonstrated that improvements can be made to cleaning processes with fluorescent markers through a simpler approach that provides a qualitative efficiency measurement of the cleaning process. Measurement of surface hygiene using ATP bioluminometers is thought to provide a more quantitative surrogate of surface cleanliness.

Type
Research Briefs
Copyright
Copyright © The Society for Healthcare Epidemiology of America 2013

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Griffith, CJ, Cooper, RA, Gilmore, J, Davies, C, Lewis, M. An evaluation of hospital cleaning regimes and standards. J Hosp Infect 2000;45:1928.Google Scholar
2.Wilson, F, Wells, A. Evaluating environmental cleanliness in hospital and other healthcare settings. Healthc Infect 2012;17:70.Google Scholar
3.Boyce, JM, Havill, NL, Dumigan, DG, Golebiewski, M, Balogun, O, Rizvani, R. Monitoring the effectiveness of hospital cleaning practices by use of an adenosine triphosphate bioluminescence assay. Infect Control Hosp Epidemiol 2009;30:678684.Google Scholar
4.Carling, PC, Parry, MM, Rupp, ME, Po, JL, Dick, B, Von Beheren, S; Healthcare Environmental Hygiene Study Group. Improving the environment surrounding patients in 36 acute care hospitals. Infect Control Hosp Epidemiol 2008;29:10351041.CrossRefGoogle ScholarPubMed
5.Boyce, JM, Havill, NL, Havill, HL, Mangione, E, Dumigan, DG, Moore, BA. Comparison of fluorescent marker systems with 2 quantitative methods of assessing terminal cleaning practices. Infect Control Hosp Epidemiol 2011;32:11871193.Google Scholar
6.Lewis, T, Griffith, CJ, Gallo, M, Weinbren, M. A modified ATP benchmark for evaluating the cleaning of some hospital environmental surfaces. J Hosp Infect 2008;69:156163.Google Scholar
7.Mulvey, D, Redding, P, Robertson, C, et al.Finding a benchmark for monitoring hospital cleanliness. J Hosp Infect 2011;77:2530.Google Scholar
8.Whiteley, GS, Derry, C, Glasbey, T. The comparative performance of three brands of portable ATP-bioluminometer intended for use in hospital infection control. Healthc Infect 2012;17:9197.Google Scholar
9.Aiken, ZA, Wilson, M, Pratten, J. Evaluation of ATP bioluminescence assays for potential use in a hospital setting. Infect Control Hosp Epidemiol 2011:32;507509.Google Scholar
10.Shama, G, Malik, DJ. The uses and abuses of rapid biolumines-cence-based ATP assays. Int J Hyg Environ Health 2013;216:115125.Google Scholar
11.Carrick, K, Barney, M, Navarro, A, Ryder, D. The comparison of four bioluminometers and their swab kits for instant hygiene monitoring and detection of microorganisms in the brewery. J Inst Brew 2001;107:3137.Google Scholar