Limitations of Forehead Infrared Body Temperature Detection for Fever Screening for Severe Acute Respiratory Syndrome

Published online by Cambridge University Press:  02 January 2015

Chuan-Chuan Liu
Affiliation:
Department of Clinical Physiology, Mackay Memorial Hospital, Taipei Department of Medical Technology, Yuanpei University of Science and Technology, Hsin-Chu, Taiwan
Ray-E Chang*
Affiliation:
Graduate Institute of Health Care Organization Administration, College of Public Health, National Taiwan University, Taipei, Taiwan
Wen-Cheng Chang
Affiliation:
Office of Deputy Superintendent, Mackay Memorial Hospital, Taipei, Taiwan
*
Graduate Institute of Health Care Organization Administration, College of Public Health, National Taiwan University, No. 19, Su-Chow Rd., #306, Taipei, Taiwan

Abstract

We investigated alternative measurement methodology for infrared body thermometry to increase accuracy for outdoor fever screening during the 2003 SARS epidemic. Our results indicate that the auditory meatus temperature is a superior alternative compared with the forehead body surface temperature due to its close approximation to the tympanic temperature.

Type
Concise Communications
Copyright
Copyright © The Society for Healthcare Epidemiology of America 2004

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Patel, N, Smith, CE, Pinchak, AC, Hagen, JF. Comparison of esophageal, tympanic, and forehead skin temperatures in adult patients. J Clin Anesth 1996;8:462468.Google Scholar
2.Shann, F, Mackenzie, A. Comparison of rectal, axillary, and forehead temperatures. Arch Pediatr Adolesc Med 1996;150:7478.Google Scholar
3.World Health Organization. Consensus Document on the Epidemiology of Severe Acute Respiratory Syndrome (SARS). Geneva: World Health Organization; 2003:3.Google Scholar
4.Craig, JV, Lancaster, GA, Taylor, S, Williamson, PR, Smyth, RL. Infrared ear thermometry compared with rectal thermometry in children: a systematic review. Lancet 2002;360:603609.CrossRefGoogle ScholarPubMed
5.Jensen, BN, Jensen, FS, Madsen, SN, Lossl, K. Accuracy of digital tympanic, oral, axillary, and rectal thermometers compared with standard rectal mercury thermometers. Eur J Surg 2000;166:848851.CrossRefGoogle ScholarPubMed
6.Giuliano, KK, Giuliano, AJ, Scott, SS, et al.Temperature measurement in critically ill adults: a comparison of tympanic and oral methods. Am J Crit Care 2000;9:254261.Google Scholar
7.Manian, FA, Griesenauer, S. Lack of agreement between tympanic and oral temperature measurement in adult hospitalized patients. Am J Infect Control 1998;26:428430.CrossRefGoogle ScholarPubMed
8.Kocoglu, H, Goksu, S, Isik, M, Akturk, Z, Bayazit, YA. Infrared tympanic thermometer can accurately measure the body temperature in children in an emergency room setting. Int J Pediatr Otorhinolaryngol 2002;65:3943.CrossRefGoogle Scholar
9.Gilbert, M, Barton, AJ, Counsell, CM. Comparison of oral and tympanic temperatures in adult surgical patients. Appl Nurs Res 2002;15:4247.Google Scholar
10.Fritz, U, Rohrberg, M, Lange, C, Weyland, W, Brauer, A, Braun, U. Infrared thermometry in the auditory canal: evaluation on the Diatek 9000 Instatemp and Diatek 9000 Thermoguide. Anaesthesist 1996;45:10591066.Google Scholar
11.Chamberlain, JM, Terndrup, TE, Alexander, DT, et al.Determination of normal ear temperature with an infrared emission detection thermometer. Ann Emerg Med 1995;25:1520.CrossRefGoogle ScholarPubMed
12.Sloan, RE. SARS: screening, disease associations, and response. Lancet 2003;361:1905.CrossRefGoogle ScholarPubMed