Hostname: page-component-cd9895bd7-q99xh Total loading time: 0 Render date: 2024-12-23T04:10:51.328Z Has data issue: false hasContentIssue false

Findings of the International Nosocomial Infection Control Consortium (INICC), Part III Effectiveness of a Multidimensional Infection Control Approach to Reduce Central Line—Associated Bloodstream Infections in the Neonatal Intensive Care Units of 4 Developing Countries

Published online by Cambridge University Press:  02 January 2015

Victor Daniel Rosenthal*
Affiliation:
International Nosocomial Infection Control Consortium, Buenos Aires, Argentina
Lourdes Dueñas
Affiliation:
Hospital Nacional de Niños Benjamin Bloom, San Salvador, El Salvador
Martha Sobreyra-Oropeza
Affiliation:
Hospital de la Mujer, Mexico City, Mexico
Khaldi Ammar
Affiliation:
Hôpital d'Enfants, Tunis, Tunisia
Josephine Anne Navoa-Ng
Affiliation:
St. Luke's Medical Center, Quezon City, Philippines
Ana Conceptión Bran de Casares
Affiliation:
Hospital Nacional de Niños Benjamin Bloom, San Salvador, El Salvador
Lilian de Jesús Machuca
Affiliation:
Hospital Nacional de Niños Benjamin Bloom, San Salvador, El Salvador
Nejla Ben-Jaballah
Affiliation:
Hôpital d'Enfants, Tunis, Tunisia
Asma Hamdi
Affiliation:
Hôpital d'Enfants, Tunis, Tunisia
Victoria D. Villanueva
Affiliation:
St. Luke's Medical Center, Quezon City, Philippines
María Corazon V. Tolentino
Affiliation:
St. Luke's Medical Center, Quezon City, Philippines
*
Corrientes Avenue No. 4580, Floor 12, Apt. D, Buenos Aires 1195, Argentina ([email protected], http://www.inicc.org)

Abstract

Objective.

To analyze the impact of the International Nosocomial Infection Control Consortium (INICC) multidimensional infection control approach to reduce central line-associated bloodstream infection (CLABSI) rates.

Setting.

Four neonatal intensive care units (NICUs) of INICC member hospitals from El Salvador, Mexico, Philippines, and Tunisia.

Patients.

A total of 2,241 patients hospitalized in 4 NICUs for 40,045 bed-days.

Methods.

We conducted a before-after prospective surveillance study. During Phase 1 we performed active surveillance, and during phase 2 the INICC multidimensional infection control approach was implemented, including the following practices: (1) central line care bundle, (2) education, (3) outcome surveillance, (4) process surveillance, (5) feedback of CLABSI rates, and (6) performance feedback of infection control practices. We compared CLABSI rates obtained during the 2 phases. We calculated crude stratified rates, and, using random-effects Poisson regression to allow for clustering by ICU, we calculated the incidence rate ratio (IRR) for each follow-up time period compared with the 3-month baseline.

Results.

During phase 1 we recorded 2,105 CL-days, and during phase 2 we recorded 17,117 CL-days. After implementation of the multidimensional approach, the CLABSI rate decreased by 55%, from 21.4 per 1,000 CL-days during phase 1 to 9.7 per 1,000 CL-days during phase 2 (rate ratio, 0.45 [95% confidence interval, 0.33–0.63]). The IRR was 0.53 during the 4–12-month period and 0.07 during the final period of the study (more than 45 months).

Conclusions.

Implementation of a multidimensional infection control approach was associated with a significant reduction in CLABSI rates in NICUs.

Type
Original Article
Copyright
Copyright © The Society for Healthcare Epidemiology of America 2013

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Marschall, J, Mermel, LA, Classen, D, et al. Strategies to prevent central line-associated bloodstream infections in acute care hospitals. Infect Control Hosp Epidemiol 2008;29(suppl 1):S22S30.Google Scholar
2. Pronovost, P, Needham, D, Berenholtz, S, et al. An intervention to decrease catheter-related bloodstream infections in the ICU. N Engl J Med 2006;355(26):27252732.Google Scholar
3. Digiovine, B, Chenoweth, C, Watts, C, Higgins, M. The attributable mortality and costs of primary nosocomial bloodstream infections in the intensive care unit. Am J Respir Crit Care Med 1999; 160(3):976981.Google Scholar
4. Warren, DK, Quadir, WW, Hollenbeak, CS, Elward, AM, Cox, MJ, Fraser, VJ. Attributable cost of catheter-associated bloodstream infections among intensive care patients in a nonteaching hospital. Crit Care Med 2006;34(8):20842089.CrossRefGoogle Scholar
5. Powers, RJ, Wirtschafter, DW. Decreasing central line associated bloodstream infection in neonatal intensive care. Clin Perinatol 2010;37(1):247272.Google Scholar
6. Barnett, AG, Beyersmann, J, Allignol, A, Rosenthal, VD, Graves, N, Wolkewitz, M. The time-dependent bias and its effect on extra length of stay due to nosocomial infection. Value Health 2011; 14(2):381386.Google Scholar
7. Higuera, F, Rangel-Frausto, MS, Rosenthal, VD, et al. Attributable cost and length of stay for patients with central venous catheter-associated bloodstream infection in Mexico City intensive care units: a prospective, matched analysis. Infect Control Hosp Epidemiol 2007;28(1):3135.CrossRefGoogle ScholarPubMed
8. Rosenthal, VD, Guzman, S, Migone, O, Crnich, CJ. The attributable cost, length of hospital stay, and mortality of central line-associated bloodstream infection in intensive care departments in Argentina: a prospective, matched analysis. Am J Infect Control 2003;31(8):475480.Google Scholar
9. Rosenthal, VD, Guzman, S, Migone, O, Safdar, N. The attributable cost and length of hospital stay because of nosocomial pneumonia in intensive care units in 3 hospitals in Argentina: a prospective, matched analysis. Am J Infect Control 2005;33(3): 157161.Google Scholar
10. Rosenthal, VD, Udwadia, FE, Muñoz, HJ, et al. Time-dependent analysis of extra length of stay and mortality due to ventilator-associated pneumonia in intensive-care units of ten limited-resources countries: findings of the International Nosocomial Infection Control Consortium (INICC). Epidemiol Infect 2011; 139(11):17571763.Google Scholar
11. Rosenthal, VD, Dwivedy, A, Calderon, ME, et al. Time-dependent analysis of length of stay and mortality due to urinary tract infections in ten developing countries: INICC findings. J Infect 2011;62(2):136141.Google Scholar
12. Barnett, AG, Graves, N, Rosenthal, VD, Salomao, R, Rangel-Frausto, MS. Excess length of stay due to central line-associated bloodstream infection in intensive care units in Argentina, Brazil, and Mexico. Infect Control Hosp Epidemiol 2010;31(11): 11061114.CrossRefGoogle ScholarPubMed
13. Ramirez Barba, EJ, Rosenthal, VD, Higuera, F, et al. Device-associated nosocomial infection rates in intensive care units in four Mexican public hospitals. Am J Infect Control 2006;34(4): 244247.CrossRefGoogle ScholarPubMed
14. Rosenthal, VD. Device-associated nosocomial infections in limited-resources countries: findings of the International Nosocomial Infection Control Consortium (INICC). Am J Infect Control 2008;36(10):S171.e7-S171.el2.Google Scholar
15. Rosenthal, VD, Guzman, S, Orellano, PW. Nosocomial infections in medical-surgical intensive care units in Argentina: attributable mortality and length of stay. Am J Infect Control 2003;31(5): 291295.Google Scholar
16. Tarricone, R, Torbica, A, Franzetti, F, Rosenthal, VD. Hospital costs of central line-associated bloodstream infections and cost-effectiveness of closed vs. open infusion containers: the case of intensive care units in Italy. Cost Eff Resour Alloc 2010;8:8.Google Scholar
17. Moreno, CA, Rosenthal, VD, Olarte, N, et al. Device-associated infection rate and mortality in intensive care units of 9 Colombian hospitals: findings of the International Nosocomial Infection Control Consortium. Infect Control Hosp Epidemiol 2006; 27(4):349356.CrossRefGoogle ScholarPubMed
18. Rosenthal, VD, Guzman, S, Crnich, C. Device-associated nosocomial infection rates in intensive care units of Argentina. Infect Control Hosp Epidemiol 2004;25(3):251255.Google Scholar
19. Rosenthal, VD, Lynch, P, Jarvis, WR, et al. Socioeconomic impact on device-associated infections in limited-resource neonatal intensive care units: findings of the INICC. Infection 2011;39(5): 439450.CrossRefGoogle ScholarPubMed
20. Townsend, TR, Wenzel, RP. Nosocomial bloodstream infections in a newborn intensive care unit: a case-matched control study of morbidity, mortality and risk. Am J Epidemiol 1981;114(1): 7380.Google Scholar
21. Pessoa-Silva, CL, Miyasaki, CH, de Almeida, MF, Kopelman, BI, Raggio, RL, Wey, SB. Neonatal late-onset bloodstream infection: attributable mortality, excess of length of stay and risk factors. Eur J Epidemiol 2001;17(8):715720.Google Scholar
22. Stoli, BJ, Hansen, N, Fanaroff, AA, et al. Late-onset sepsis in very low birth weight neonates: the experience of the NICHD Neonatal Research Network. Pediatrics 2002;110(2 pt 1):285291.Google Scholar
23. Stoll, BJ, Hansen, NI, Adams-Chapman, I, et al. Neurodevelopmental and growth impairment among extremely low-birth-weight infants with neonatal infection. JAMA 2004;292(19): 23572365.CrossRefGoogle ScholarPubMed
24. Shah, DK, Doyle, LW, Anderson, PJ, et al. Adverse neurodevelopment in preterm infants with postnatal sepsis or necrotizing enterocolitis is mediated by white matter abnormalities on magnetic resonance imaging at term. J Pediatr 2008;153(2):170175, 175.el.CrossRefGoogle ScholarPubMed
25. Lahra, MM, Beeby, PJ, Jeffery, HE. Intrauterine inflammation, neonatal sepsis, and chronic lung disease: a 13-year hospital cohort study. Pediatrics 2009;123(5):13141319.Google Scholar
26. Hermans, D, Talbotec, C, Lacaille, F, Goulet, O, Ricour, C, Colomb, V. Early central catheter infections may contribute to hepatic fibrosis in children receiving long-term parenteral nutrition. J Pediatr Gastroenterol Nutr 2007;44(4):459463.CrossRefGoogle ScholarPubMed
27. Eggimann, P, Harbarth, S, Constantin, MN, Touveneau, S, Chevrolet, JC, Pittet, D. Impact of a prevention strategy targeted at vascular-access care on incidence of infections acquired in intensive care. Lancet 2000;355(9218):18641868.Google Scholar
28. Apisarnthanarak, A, Thongphubeth, K, Yuekyen, C, Warren, DK, Fraser, VJ. Effectiveness of a catheter-associated bloodstream infection bundle in a Thai tertiary care center: a 3-year study. Am J Infect Control 2010;38(6):449455.Google Scholar
29. Rosenthal, VD, Ramachandran, B, Dueñas, L. Findings of the International Nosocomial Infection Control Consortium (INICC), part I: effectiveness of a multidimensional infection control approach on catheter-associated urinary tract infection rates in pediatric intensive care units of 6 developing countries. Infect Control Hosp Epidemiol 2012;33(7):696703.Google Scholar
30. Horan, TC, Andrus, M, Dudeck, MA. CDC/NHSN surveillance definition of health care-associated infection and criteria for specific types of infections in the acute care setting. Am J Infect Control 2008;36(5):309332.CrossRefGoogle ScholarPubMed
31. Rosenthal, VD, Guzman, S, Safdar, N. Reduction in nosocomial infection with improved hand hygiene in intensive care units of a tertiary care hospital in Argentina. Am J Infect Control 2005; 33(7):392397.Google Scholar
32. Berenholtz, SM, Pronovost, PJ, Lipsett, PA, et al. Eliminating catheter-related bloodstream infections in the intensive care unit. Crit Care Med 2004;32(10):20142020.CrossRefGoogle ScholarPubMed
33. Raad, II, Hohn, DC, Gilbreath, BJ, et al. Prevention of central venous catheter-related infections by using maximal sterile barrier precautions during insertion. Infect Control Hosp Epidemiol 1994;15(4 pt 1):231238.Google Scholar
34. O'Grady, NP, Alexander, M, Burns, LA, et al. Guidelines for the prevention of intravascular catheter-related infections. Clin Infect Dis 2011;52(9):e162e193.CrossRefGoogle ScholarPubMed
35. Pratt, RJ, Pellowe, CM, Wilson, JA, et al. epic2: national evidence-based guidelines for preventing healthcare-associated infections in NHS hospitals in England. J Hosp Infect 2007;65(suppl 1): S1S64.Google Scholar
36. Casey, AL, Worthington, T, Lambert, PA, Quinn, D, Faroqui, MH, Elliott, TS. A randomized, prospective clinical trial to assess the potential infection risk associated with the PosiFlow needleless connector. J Hosp Infect 2003;54(4):288293.Google Scholar
37. Luebke, MA, Arduino, MJ, Duda, DL, et al. Comparison of the microbial barrier properties of a needleless and a conventional needle-based intravenous access system. Am J Infect Control 1998;26(4):437441.Google Scholar
38. Parenti, CM, Lederle, FA, Impola, CL, Peterson, LR. Reduction of unnecessary intravenous catheter use: internal medicine house staff participate in a successful quality improvement project. Arch Intern Med 1994;154(16):18291832.Google Scholar
39. Lederle, FA, Parenti, CM, Berskow, LC, Ellingson, KJ. The idle intravenous catheter. Ann Intern Med 1992;116(9):737738.Google Scholar
40. O'Grady, NP, Alexander, M, Burns, LA, et al. Guidelines for the prevention of intravascular catheter-related infections. Am J Infect Control 2011;39(4 suppl 1):S1S34.Google Scholar
41. Royer, T. Implementing a better bundle to achieve and sustain a zero central line-associated bloodstream infection rate. J Infus Nurs 2010;33(6):398406.Google Scholar
42. Rosenthal, VD, Maki, DG, Graves, N. The International Nosocomial Infection Control Consortium (INICC): goals and objectives, description of surveillance methods, and operational activities. Am J Infect Control 2008;36(9):e1e12.CrossRefGoogle ScholarPubMed
43. Sax, H, Allegranzi, B, Chraiti, MN, Boyce, J, Larson, E, Pittet, D. The World Health Organization hand hygiene observation method. Am J Infect Control 2009;37(10):827834.Google Scholar
44. Maki, DG, Weise, CE, Sarafin, HW. A semiquantitative culture method for identifying intravenous-catheter-related infection. N Engl J Med 1977;296(23):13051309.Google Scholar
45. Emori, TG, Culver, DH, Horan, TC, et al. National nosocomial infections surveillance system (NNIS): description of surveillance methods. Am J Infect Control 1991;19(1):1935.CrossRefGoogle ScholarPubMed
46. World Bank classification of economies. World Bank website. http://web.worldbank.org/WBSITE/EXTERNAL/DATA STATISTICS/0,,contentMDK:20421402~pagePK:64133150~piPK:64133175~theSitePK:239419,00.html. Published 2007. Accessed October 5, 2008.Google Scholar
47. Tseng, YC, Chiu, YC, Wang, JH, Lin, HC, Su, BH, Chiu, HH. Nosocomial bloodstream infection in a neonatal intensive care unit of a medical center: a three-year review. J Microbiol Immunol Infect 2002;35(3):168172.Google Scholar
48. Landre-Peigne, C, Ka, AS, Peigne, V, Bougere, J, Seye, MN, Imbert, P. Efficacy of an infection control programme in reducing nosocomial bloodstream infections in a Senegalese neonatal unit. J Hosp Infect 2011;79(2):161165.Google Scholar
49. Mahieu, LM, De Dooy, JJ, Lenaerts, AE, leven, MM, De Muynck, AO. Catheter manipulations and the risk of catheter-associated bloodstream infection in neonatal intensive care unit patients. J Hosp Infect 2001;48(1):2026.Google Scholar
50. Pronovost, PJ, Marsteller, JA, Goeschel, CA. Preventing bloodstream infections: a measurable national success story in quality improvement. Health Aff (Millwood) 2011;30(4):628634.CrossRefGoogle ScholarPubMed
51. Schulman, J, Stricof, R, Stevens, TP, et al. Statewide NICU central-line-associated bloodstream infection rates decline after bundles and checklists. Pediatrics 2011;127(3):436444.Google Scholar
52. Haley, RW, Quade, D, Freeman, HE, Bennett, JV. The SENIC Project: study on the efficacy of nosocomial infection control (SENIC Project): summary of study design. Am J Epidemiol 1980;111(5):472485.Google Scholar
53. Hughes, JM. Study on the efficacy of nosocomial infection control (SENIC Project): results and implications for the future. Chemotherapy 1988;34(6):553561.Google Scholar
54. Rosenthal, VD, Maki, DG, Rodrigues, C, et al. Impact of International Nosocomial Infection Control Consortium (INICC) strategy on central line-associated bloodstream infection rates in the intensive care units of 15 developing countries. Infect Control Hosp Epidemiol 2010;31(12):12641272.CrossRefGoogle ScholarPubMed
55. Edwards, JR, Peterson, KD, Mu, Y, et al. National Healthcare Safety Network (NHSN) report: data summary for 2006 through 2008, issued December 2009. Am J Infect Control 2009;37(10): 783805.Google Scholar
56. Rosenthal, VD, Jarvis, WR, Jamulitrat, S, et al. Socioeconomic impact on device-associated infections in pediatric intensive care units of 16 limited-resource countries: International Nosocomial Infection Control Consortium findings. Pediatr Crit Care Med 2012;13(4):399406.Google Scholar